23
Users manual |
11.2 Connector Pinouts
Blue ACN Connector and Yellow Sync Connector
Accept LEMO FGG.0B.305 and compatible push-pull plugs
Connectors carry TC in and out as per industry standard,
plus sync on one and ACN metadata on the other.
They accept Lemo FGG.0B.305 compatible push-pull plugs.
Hirose
Primary DC port, connect your external power supply here.
Trilevel Sync Out Impedance 75Ω / Dual Load: 38Ω
LTC Out Impedance 1kΩ
LTC In Impedance 15kΩ
Antennas
SMA type F, leave supplied antenna attached, only substitute with
original replacements ANT-2.4-SMA-M(90)
ACN
SYNC
(yellow cable)
1
GND
GND
2
TC in
TC in
3
ACN TX
PPF out
4
ACN RX
Sync out
5
TC out
TC out
Hirose HR10-7P-4P or compatible
1
GND
2
NC
3
NC
4
6-24V DC
1
5
4
2
3
2
1
3
4