Ambient Weather WS-8460 Скачать руководство пользователя страница 4

 

Version 1.0  

 

©Copyright 2016, Ambient LLC. All Rights Reserved. 

 

 

 

Page 4 

No 

Description 

No 

Description 

Alarm/Snooze Button 

- Stop the current alarm when sounding and 
enter into snooze mode. 
- Press and hold for two seconds to stop the 
current alarm when sounding for 24 hours. 

12 

FOCUS Knob 

- Adjust the focus of the projected time 
and temperature. 

Reverse Button 

Press to reverse the projection 180 degrees. 

13 

RESET Button 

- Press to reset all values to default 
values. 
- In case of malfunction, the unit can be 
reset.

 

Projector 

- Projects the time and indoor/outdoor 
temperature (automatically scrolls between 
indoor and outdoor temperature every 5 
seconds). 

14 

CHANNEL/UP Button 

- In set mode, press to increase the 
values (press and hold to change 
rapidly). 
- In normal time display mode, press to 
switch between Remote Sensor 
Channels 1, 2 and 3. 
- In normal time display mode, press 
and hold for 2 seconds to automatically 
scroll between sensor channels 1, 2 and 
3. 

LCD Display 

15 

12/24 / DOWN Button 

- In set mode, press to decrease the 
values.(press and hold to change 
rapidly) 
- In normal time mode, press to switch 
between 12 and 24 hour format. 

Time Button 

- Press to switch between Month/Date and 
alarm time mode (Alarm 1 and 2). 
- Press and hold for 2 seconds to enter time 
set mode. 
- In time set mode, press to step through the 
different time and date settings. 

16 

HISTORY Button 

- In normal mode, press to view hourly 
historical data stored in memory (last 72 
hours). 

ALARM Button 

- In normal time display mode, Press TIME 
button to display ALM1 & ALM2. 
Press 

ALARM

 to turn on/off ALM1 & 

ALM2. 
- Press to stop the current alarm when the 
alarm is ringing and turn off the alarm and 
snooze function. 
- In alarm time mode, press and hold for 2 
seconds to enter alarm time setting mode. 
- In alarm time setting mode, press to step 
through the different time and date settings. 

17 

BARO Button 

- Press to switch pressure units of 
measure between hPa, inHg and mmHg. 
- Press and hold for 2 seconds to switch 
between relative pressure and absolute 
pressure. 
- In relative pressure mode (REL is 
flashing), press BARO to enter the 
relative pressure calibration mode. Press 
BARO again to save and exit the 
settings, or 
the clock will automatically exit in 60 
seconds without pressing any key. 
- In absolute pressure mode, press 
BARO to save and exit the setting. 

MAX / MIN Button 

- Press to display the maximum and 

18 

°F/°C Switch 

- Select switch between °F and °C units 

Содержание WS-8460

Страница 1: ...Rotation 9 5 3 2 Adjusting Projector Focus 9 5 4 Barometric Pressure Display and Settings 9 5 4 1 Barometric Pressure Units of Measure 9 5 4 2 Absolute Pressure vs Relative Pressure 9 5 4 3 Relative Pressure Calibration 9 5 5 The Barograph 10 5 6 Viewing Minimum and Maximum Records Memory Mode 11 5 7 Viewing Historical Data History Mode 11 5 8 Color Changing Feature 11 5 8 1 Manual Color Preferenc...

Страница 2: ...ature and Color Changing Outdoor Temperature The following user guide provides step by step instructions for installation operation and troubleshooting To download the latest full sized manual and additional troubleshooting tips please visit http ambientweather wikispaces com ws8460 2 Warnings Warning Never look directly into the time and temperature projector for a prolonged period of time This c...

Страница 3: ...Version 1 0 Copyright 2016 Ambient LLC All Rights Reserved Page 3 3 Getting Started 3 1Product Features 3 1 1 Display Clock Figure 1 ...

Страница 4: ...een 12 and 24 hour format 5 Time Button Press to switch between Month Date and alarm time mode Alarm 1 and 2 Press and hold for 2 seconds to enter time set mode In time set mode press to step through the different time and date settings 16 HISTORY Button In normal mode press to view hourly historical data stored in memory last 72 hours 6 ALARM Button In normal time display mode Press TIME button t...

Страница 5: ...e to the HI position to brighten the backlight Slide to the LO position to dim backlight 10 RAINBOW Button Press RAINBOW button and the backlight will change color as follows white red orange yellow green cyan blue purple 21 AC Jack AC 6V 300mA 11 TUNE Button Press and hold the TUNE button to fine tune the color The backlight will automatically display 256colors Let go of the TUNE button to stop a...

Страница 6: ...the DC jack of the clock 3 Once the wireless transmitter has synced up to the clock you can place the sensor outside Note If no display is present after powering up the clock press the reset button on the back of the clock 3 4 Siting the Wireless Transmitter Outside It is recommended you place the remote sensor in a shaded area Direct sunlight and radiant heat sources will result in inaccurate tem...

Страница 7: ...w Battery Indicator 2 Time Time Alarm 8 Wireless signal strength indicator 3 Alarm 1 9 Indoor Temperature 4 Alarm 2 10 Barograph 5 Wireless Channel Indicator 1 2 or 3 11 Relative Absolute Pressure 6 Wireless Temperature channels 1 2 or 3 Figure 3 5 Settings 5 1Time Date and Language Settings While in normal time mode perform the following operations to set date time and language ...

Страница 8: ...Press the TIME button again to set ALARM2 Once ALARM1 or ALARM2 are displayed in the date field see Figure 3 No 10 perform the following Command Mode Settings ALARM 2 seconds Enter Alarm Settings Alarm Hour Press UP to increase DOWN to decrease ALARM Alarm Minute Press UP to increase DOWN to decrease ALARM Exit Alarm Settings ALARM 2 seconds means press and hold the ALARM button for two seconds AL...

Страница 9: ...ometric units of measure hPa inHg mmHg 5 4 2 Absolute Pressure vs Relative Pressure Press and hold the BARO button for 2 seconds to enter barometric mode and press the UP button to switch between the relative and absolute pressure reading 5 4 3 Relative Pressure Calibration Please Reference Section 5 4 3 1 for details on the purpose of calibrating relative pressure and how to calibrate relative pr...

Страница 10: ...onsidered high pressure and relative pressure measurements less than 29 92 inHg are considered low pressure To determine the relative pressure for your location locate an official reporting station near you the internet is the best source for real time barometer conditions such as Weather com or Wunderground com and set your weather station to match the official reporting station 5 5 The Barograph...

Страница 11: ...and hold MAX MIN for two seconds to reset the minimum indoor temperature to the current value MAX MIN Displays Maximum Barometer and the associated date and time Press and hold MAX MIN for two seconds to reset the maximum barometer to the current value MAX MIN Displays Minimum Barometer and the associated date and time Press and hold MAX MIN for two seconds to reset the minimum barometer to the cu...

Страница 12: ...ain to stop at the color you prefer 5 8 2 Outdoor Temperature Color Press the OUTDOOR TEMP button to automatically change the backlight as a function of temperature The display color will automatically change based on the color chart below Temperature Range F Color 1 0 White 2 0 10 Violet 3 10 20 Dark Blue 4 20 30 Light Blue 5 30 40 Dark Aqua 6 40 50 Light Aqua 7 50 60 Green 8 60 70 Light Green 9 ...

Страница 13: ...the beep will sound The wireless channels will scroll on the screen every 5 seconds 5 13 Syncing and Resyncing the Wireless Sensor If the sensor is synced to the console the console will display the reception icon with the signal strength If the sensor signal is lost dashes will be displayed in place of temperature If you lose synchronization from the remote wireless sensor for an extended period ...

Страница 14: ... provides specifications for the measured parameters Measurement Range Accuracy Resolution Indoor Temperature 32 to 113 F 2 F 0 1 Outdoor Temperature 4 to 140 F alkaline batteries 22 to 140 F Lithium e2 Energizer batteries 2 F 0 1 Barometer 540mb to 1100mb 15 95 inHg to 32 48 inHg Altitude Range 2 291 to 16 413 698 to 5000 meters 8mb 540 to 969mb 25 C 5mb 970 to 1030mb 25 C 8mb 1031 to 1100mb 25 C...

Страница 15: ...er location Radio Frequency RF Sensors cannot transmit through metal barriers example aluminum siding or multiple thick walls The clock does not respond to commands Press the reset button on the back of the clock with an open ended paper clip or sharp tool The projection is fuzzy Adjust the focus setting 8 Accessories Accessory Description TX 8300 Additional wireless sensor 9 Liability Disclaimer ...

Страница 16: ...e is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the...

Страница 17: ...ty to receive a signal due to any source of interference or metal obstructions and 7 extreme acts of nature such as lightning strikes or floods This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resul...

Отзывы: