Ambient Weather WS-14 Скачать руководство пользователя страница 16

 

Version 1.1  

 

©Copyright 2014, Ambient LLC. All Rights Reserved. 

 

 

 

Page 16 

9

 

Liability Disclaimer 

Please help in the preservation of the environment and return used batteries to an authorized depot.   
The  electrical  and  electronic  wastes  contain  hazardous  substances.  Disposal  of  electronic  waste  in 
wild country and/or in unauthorized grounds strongly damages the environment. 
 
Reading the “User manual” is highly recommended. The manufacturer and supplier cannot accept any 
responsibility for any incorrect readings and any consequences that occur should an inaccurate reading 
take place. 
 
This product is designed for use in the home only as indication of weather conditions. This product is 
not to be used for medical purposes or for public information. 
 
The specifications of this product may change without prior notice. 
 
This product is not a toy. Keep out of the reach of children. 
 
No part of this manual may be reproduced without written authorization of the manufacturer. 
 
Ambient,  LLC  WILL  NOT  ASSUME  LIABILITY  FOR  INCIDENTAL,  CONSEQUENTIAL, 
PUNITIVE,  OR  OTHER  SIMILAR  DAMAGES  ASSOCIATED  WITH  THE  OPERATION  OR 
MALFUNCTION OF THIS PRODUCT. 

10

 

FCC Statement 

Statement according to FCC part 15.19: 

 

This device complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions:   

1.

 

This device may not cause harmful interference.   

2.

 

This device must accept any interference received, including interference that may cause 
undesired operation.   
 

Statement according to FCC part 15.21: 

 

Modifications not expressly approved by this company could void the user's authority to operate the 
equipment. 

Statement according to FCC part 15.105: 

 

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses and 
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications.   
However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined 
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:   

 

Reorient or relocate the receiving antenna.   

 

Increase the separation between the equipment and receiver.   

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.   

 

Consult the dealer or an experienced radio/TV technician for help.   

 

Содержание WS-14

Страница 1: ... 1 Rate of Change Icon 10 5 2 Console Operation 11 5 2 1 Set Mode 11 5 2 2 Viewing the High and Low Alarms 11 5 2 3 Alarm Defaults 11 5 2 4 Setting the Min and Max Alarm 11 5 3 Manually Reset Max Min 12 5 4 Channel Selection 12 5 5 Sensor Search Mode 12 5 6 Best Practices for Wireless Communication 12 5 7 Adjustment or Calibration 13 5 7 1 Remote Sensor Temperature Calibration 13 5 7 2 Indoor Cons...

Страница 2: ...g sensors and receivers additional sensors and receivers are sold separately Item Number Image Description F007T 8 channel sensor measures temperature Applications include indoor and outdoor air temperature measurement F007TP 8 channel sensor measures probe temperature Applications include refrigerators and freezers where the probe is placed inside the appliance s and the display is outside water ...

Страница 3: ...r F007PF for pool spa Dimensions LxHxW 8 5 x 4 2 x 3 7 216 x 106 x 95mm LCD Dimensions LxW 1 1 x 0 62 27 x 16mm Remote sensor depth 7 1 180mm 1 Display Console Frame Dimensions LxHxW 4 0 x 2 95 x 1 00 in LCD Dimensions LxW 1 96 x 1 77 LCD Segment Height 0 78 inches 1 User Manual 2 2 Floating Pool and Spa Thermometer Sensor Set Up Note We recommend fresh alkaline batteries for temperature ranges be...

Страница 4: ... the main body of the sensor by removing the lid as shown in Figure 2 Figure 2 2 The floating thermometer includes dip switches for assigning channel numbers BEFORE inserting the batteries locate the dip switches on the inside cover of the lid of the transmitter Figure 3 displays all four switches in the OFF position factory default setting Figure 3 ...

Страница 5: ...C change Dip Switch 4 as referenced in Table 1 DIP SWITCH FUNCTION 1 2 3 4 DOWN DOWN DOWN Channel 1 DOWN DOWN UP Channel 2 optional DOWN UP DOWN Channel 3 optional DOWN UP UP Channel 4 optional UP DOWN DOWN Channel 5 optional UP DOWN UP Channel 6 optional UP UP DOWN Channel 7 optional UP UP UP Channel 8 optional DOWN F UP C Table 1 3 Reference Figure 4 Install 4 x AAA batteries Figure 4 1 Open the...

Страница 6: ...ting data 5 Verify the correct channel number CH and temperature units of measure F vs C are on the display as shown in Figure 5 Figure 5 1 temperature 2 temperature units F vs C 3 channel number 6 Close the battery door Make sure both red colored gaskets are properly seated in their traces prior to closing the battery door as shown in Figure 6 Failure to properly seal the floating thermometer wil...

Страница 7: ...t is firmly locked and the key is aligned 2 Insert the key and turn 90 degrees to lock the lid as shown in Figure 7 Figure 7 A tether can be added into the key as shown in Figure 8 Figure 8 Place the sensor in the water and make sure that it is within the effective transmission range from the display console ...

Страница 8: ...hrough solid earth or ground Figure 9 reference B Use a tether string to fix the sensor in the pool or spa ii Place the console at least three feet away from computers TVs and wireless phones iii Avoid transmitting through solid metal barriers Figure 9 3 Maintenance During each battery change 1 2 years we recommend applying waterproof silicon grease to the seals http en wikipedia org wiki Silicone...

Страница 9: ...d remove the battery cover and insert three AAA alkaline or lithium avoid rechargeable unless fully charged and high quality batteries in the back of the display console All of the LCD segments will light up for a few seconds to verify all segments are operating properly 1 Replace the battery door and place the console in the upright position with the desk stand folded out The console will instant...

Страница 10: ... the troubleshooting guide in Section 8 4 1 Display Console Layout Figure 11 4 2 Sensor Operation Verification Verify the indoor and floating pool temperature match closely in the same location about 5 to 10 apart The sensors should be within 2 F the accuracy is 1 F Allow about 30 minutes for both sensors to stabilize The temperature can be adjusted or calibrated later to match each other or a kno...

Страница 11: ...The time alarm icon will appear when set and disappear when disabled Press do not hold the SET key to advance to the next setting 6 Temperature Units of Measure Press the key to switch between F and C units of measure Press the SET key to advance to the next setting 7 Max Min Clearing The Max Min can be programmed to clear daily at midnight or manually Press the key to switch between Clears Daily ...

Страница 12: ...n Press and hold the CH button for 3 seconds and the remote search icon will be constantly displayed for up to 3 minutes Once the signal is reacquired the remote search icon will turn off and the current values will be displayed 2 If new sensors are added subtracted or multiple sensor channels are lost press and hold the CH button for 5 seconds on any channel and the remote search icon will be con...

Страница 13: ...n is to measure conditions of your surroundings which vary significantly from location to location 5 7 1 Remote Sensor Temperature Calibration Prior to entering the calibration mode press the CH button to select the remote temperature sensor you wish to adjust To enter the temperature calibration mode press and hold the SET and CH buttons at the same time for 5 seconds and the remote temperature v...

Страница 14: ...d allow the sensor to stabilize for 48 hours Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer 6 Glossary of Terms Term Definition Accuracy Accuracy is defined as the ability of a measurement to match the actual value of the quantity being measured Range Range is defined as the amount or extent a value can be measured 7 Specifications 7 1 Wirel...

Страница 15: ...e display console If the sensor assembly is too close less than 5 move the sensor assembly away from the display console Make sure the remote sensor LCD display is working and the transmitter light is flashing once per 60 seconds Install a fresh set of batteries in the remote thermo hygrometer For cold weather environments install lithium batteries Make sure the remote sensors are not transmitting...

Страница 16: ...ubject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Statement according to FCC part 15 21 Modifications not expressly approved by this company could void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equip...

Страница 17: ...lowing specified exceptions 1 damage caused by accident unreasonable use or neglect lack of reasonable and necessary maintenance 2 damage resulting from failure to follow instructions contained in your owner s manual 3 damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient LLC authorized service center 4 units used for other than home use 5 appl...

Отзывы: