Short description  

The AMB8466-M-GMM is a gateway for wired M-Bus to wireless M-Bus/OMS. The AMB8466-
M-GMM Configuration program serves to configure details of the AMB8466-M-GMM. 

The configuration of some details is only necessary if not all wired M-Bus modules can be found 
via the automatic search. In this case the connected M-Bus counters can, through this software, 
be registered manually on the GMM. 

 

We recommend using the proce

dure described in the “AMB8466-M-GMM Mount 

Instruction” documentation, when the meter address (id, version devicetype & 
manufacturer) and/or the used m-bus baudrate (300, 2400 or 9600) is not known. 

 

2

 

Requirements 

The PC or laptop is connected via a USB stick AMB8465-M. 

The software has been designed for the following 32 bit operating systems: 

  Windows XP  

  Windows Vista  

  Windows 7  

 

Native operation on 64 bit operating systems is not supported. 

To run the software an installed .NET Framework Version 3.5 or higher is required. 

The monitor of the applied PC/laptop should have a minimum resolution of 1024 x 600 pixels.  

For the AMB8465-M USB-stick an available USB-2.0-host-port and the relevant FTDI drivers on 
the PC are required. 

Quick start

 

Before starting the configurator the AMB8465-M must be connected to the USB port of the PC. 

After the start the software displays the following user menu. These functions are documented 
in the following paragraphs. 

Содержание AMB8466-M-GMM

Страница 1: ...ion devicetype manufacturer and or the used m bus baudrate 300 2400 or 9600 is not known 2 Requirements The PC or laptop is connected via a USB stick AMB8465 M The software has been designed for the f...

Страница 2: ...d COM port and if necessary performs a reconfiguration of the parameters When using the AMB8465 M stick for other programs please ensure that these programs use the following COM port settings 115200...

Страница 3: ...button again the POWER and ERROR LED s blink simultaneously Now after releasing the button the activated software immediately starts to read the configuration Alternatively you may also disconnect th...

Страница 4: ...2 5 Adapt configuration After confirmation of the success message the read out data is displayed The display is split into two tabs namely configuration of the user settings and enhanced user settings...

Страница 5: ...n from wildcards and to rather perform a detailed configuration The MeterID refers to the number of the meter the respective wildcard would be FFFFFFFF The Manufacturer Token is a manufacturer identif...

Страница 6: ...diness of configuration A write procedure requires more commands then the read out procedure Similar to that of the read procedure the success of a write procedure is also displayed by a respective me...

Страница 7: ...OK button the readiness for configuration has to be established Subsequently after the verification of the compatibility of the firmware to the configured device the firmware is transferred to the de...

Отзывы: