INSTALLATION

INSTRUCTIONS

CAUTION: 

DO NOT TAKE OFF THE PROTECTIVE P.V.C. TAPE BEFORE INSTALLING TOWEL WARMER TO 
AVOID SCRATCHING, MARKING OR GRAZING THE SURFACE. 

Setscrew

Threaded 

Long Tube

Take the threaded long tube (4) and screw it
down completely to the threaded wall-support (2)
; to adjust the distance from wall unscrew tube

Brick Wall

Plastic 

Anchor

Brick wall:

Drill the holes in the wall ø6 mm ( 1/4 inches)
and put the plastic anchor (1) into the wall;

Drywall:

Leave out the plastic anchor (1) and proceed
with step 2

STEP 1

STEP 3

STEP 5

STEP 6

STEP 2

Drywall

Anchor 

Screw

Drywall:

Fasteners should be fixed to studs or structural
members behind the drywall

If not possible on both sides, toggle bolts can
be used on one side.

Proceed laying the threaded wall-support (2)
on the hole and fasten it with the anchor bolt
screw: repeat this procedure also for the other
points marked on the wall

Fixing Screw

Bushing

BACK SIDE OF 

TOWEL WARMER

Laythe bushing (7) on the holes of the towel warmer.
And fasten it with the fixing screw (6);

Repeat this procedure also for the other connecting
holes of the towel warmer.

Install the towel warmer in the four connections as
shown in drawing. Technical Drawings can be found
on our website www.Ambaproducts.com

Threaded Wall-

Support

STEP 4

INSTALL DIGITAL HEAT CONTROLLER OR 
SWITCH — SEE PAGES 6 OR 7.

REMOVE THE PROTECTIVE P.V.C. TAPE BEFORE 

SWITCHING THE TOWEL WARMER ON

For each leg fasten the Setscrew and place the
cover onto the bracket

Содержание VEGA V2338

Страница 1: ...ta GA 30339 USA Phone 404 350 9738 Fax 404 355 0166 www ambaproducts com 3165407 IP 54 SKU Width HEIGHT Power Amps BTU V2338 26 1 4 39 250 watts 2 17 853 V2356 26 1 4 59 3 4 370 watts 3 21 1262 COMPONENTS 1 2 3 4 5 7 6 1 Plastic Anchor 2 Threaded Wall Support 3 Anchor Screw 4 Threaded Long Tube 5 Setscrew 6 Fixing Screw 7 Bushing DIGITAL HEAT CONTROLLER Please see Instructions DHC Included on all ...

Страница 2: ...ase of damaged wire or plug in case of malfunction drop or other kind of circumstance that may require adjustments or repair contact Amba Products We recommend the p V C Protective tape is left in place until the heater is fully installed please remove tape from bracket location first after the installation remove the P V C Protective tape to avoid glue residue Be careful while handling the heater...

Страница 3: ...fety Surface temperatures of appliances during normal operations are maintained below the temperature of 60 65 c 140 149 f without towels and 90 c 194 f with towels as required by following standards For residue buildup do not use extreme pressure on the surface to avoid scratches damages to the heater It is also possible to use a solvent use caution make sure to read the technical forms and norms...

Страница 4: ...ctural members behind the drywall If not possible on both sides toggle bolts can be used on one side Proceed laying the threaded wall support 2 on the hole and fasten it with the anchor bolt screw repeat this procedure also for the other points marked on the wall Fixing Screw Bushing BACK SIDE OF TOWEL WARMER Laythe bushing 7 on the holes of the towel warmer And fasten it with the fixing screw 6 R...

Страница 5: ...or use only Ensure that room trip switch is off before any operation Wrong wiring connection to the power source will cause sparks and the burning damage to the digital heat controller carefully consult the wiring diagram Do not insert foreign bodies inside the digital heat controller in order to avoid electric shocks or damages to it Do not use the digital heat controller close to combustibles pa...

Страница 6: ...HC Output cable D Towel Warmer cable E Ground faston POWER REGULATOR 1 Connect T1 A T2 B T3 D to faston T E 2 Connect L 1 A L2 B 3 Connect N 1 A N2 8 4 Connect N3 0 N4 C 5 Connect L3 0 L4 C Level Settings 1 Minimum Heat 9 Maximum Heat Can be wired in conjunction with a programmable timer CONSULT ELECTRICIAN STEP 1 STEP 2 ...

Страница 7: ...t the fastenings of the towel warmer s cable to the other section See the example below Connect one cable to the left section Electrical bridge 1 1 2 2 Connect the other cable to the right Electrical bridge 1 2 2 1 Fix the stainless steel wall plate with the provided screws Power source cable Fastening Connections Step 2 Towel warmer cable COMPONENTS WALL PLATE FASTENING CONNECTIONS SWITCH INSTALL...

Отзывы: