AMADOS-II DB 531.3 05.00
Important Informations
9
2.4
Safety advices
Before doing any repair work to the
electrical installation in particular welding
operations on the tractor or on the mounted
machine disconnect all electric couplings
to the "AMADOS-II".
2.5
Important hints for the use of the
"AMADOS-II" with the centrifugal
broadcaster or as a pure hectare
counter.
If a signal socket according to DIN 9684
standards exists on the tractor no additio-
nal sensor "X" (cardan shaft/wheel) need
to be fitted for determining the travelled
distance. The sensor "X" will then be
exchanged for a tractor specific adaptor-
cable (option). In case of an existing radar
sensor the signals can also be taken from
this socket.
In case of operating with a Unimog without
the on-board-computer "UNICOM I" the
sensor "X" should be exchanged for the
tacho adaptor (option).
When operating with a Unimog equipped
with the on-board-computer "UNICOM I"
the sensor "X" should be exchanged for an
adaptor cable (option). Herewith "UNICOM
I" and "AMADOS-II" will directly be
connectly to one another.
I
F
F
F
2.0
Important Informations
2.1
Attention Symbol
This symbol will always be found in such
places of this instruction book which
should especially b e adhered to in order to
comply with rules, adivce, hints and the
correct procedure of the operations as well
as to prevent damage to the implement.
2.2
Hint-Symbol
This symbol marks machine's specific
points which should be observed to ensure
the correct operation.
2.3
Declined use of the machine
"AMADOS-II" has exclusively been designed for the
usual operation as a display-, monitoring- and controlling
device for agricultural machinery.
Any use beyond the one stipulated above is no longer
considered as designed use. The manufacturer does
not accept any responsibility for damage resulting from
this; therefore the operator himself carries the full risk.
Under "declined use" also the adhering to the
manufacturer's prescribed operation-, maintenance- and
repair conditions as well the exclusive use of original
AMAZONE spare parts is to be understood.
"AMADOS-II" may only be operated, maintained and
repaired by such persons who have been made
acquainted with it and who have been advised about the
dangers.
All applicable accident preventive advice as well as any
further generally accepted safety-, working-, medical-
and road-traffic rules should be adhered ty.
Any damages resulting from arbitrary changes on
the "AMADOS-II" rule out the responsibility of the
manufacturer.
Before every operation and also during the operation
check your device for proper function and for sufficient
application accuracy of the machine.
Claims regarding damage not having occured on the
"AMADOS-II" itself will be rejedcted. This also applies
to damages due to application errors. Arbitrary
modifications to the "AMADOS-II" may result in damage
and therefore the manufacturer does not accept liability
for such damage.
I
F