Commissioning
AMADOS BAG0083.2 11.17
21
5.6
Carrying out spread rate check
•
During the spread rate check, the calibration factor for the prod-
uct is determined with
ο
the machine coupled with the tractor,
ο
the driven PTO shaft,
ο
the tractor at standstill.
•
The calibration factor can also be entered directly, if known.
DANGER
Secure the tractor and machine against unintentional rolling and
lowering of the tractor's three-point hydraulic system.
The calibration factor for the product determines the regulating be-
haviour of the
AMADOS
E+S
and depends on
•
the flow characteristics of the product to be spread.
•
the entered spread rate.
•
the entered working width.
•
The product flow characteristics may change even after a brief
storage period.
→
Therefore again determine the calibration factor for the product
before each use.
•
Always again determine the calibration factor for the product
ο
if the spread rate is changed.
ο
if there are deviations between the theoretical and the ac-
tual spread rate.