8
Definitions For Illuminated LED Indicators
Power ON
Alarm
CONDITION
On
Off
Normal
Flash when
Beeps
Beeps twice every
30 seconds
Utility Failure - Battery Mode
The UPS is providing power to battery and surge
protected outlets from its battery.
Flash when
Beeps
Rapid Beeping
every 1/2 second
Utility Failure - Low Battery
The UPS is providing battery power. Rapid beeping
indicates the unit will run out of power shortly.
On
Constant tone
Overload
-
Occurs when connected equipment
exceeds the listed capacity of the UPS. Turn the
UPS off, unplug at least one piece of equipment from
battery outlets, reset the circuit breaker and turn the
unit on.
Off
Constant tone
Charge Fault
-
In line mode, the battery charging
voltage is too high or too low.
Off
Constant tone
Utility Failure -
The frequency is beyond 47-63 Hz.
The UPS will not turn on in line mode.
Technical Specifications
Model
Standby UPS 600VA
Standby UPS 800VA
Capacity
600 VA / 360 W
800 VA / 450 W
Input Voltage on Utility
96V typical - 140V typical
Input Frequency
50/60 ± 3 Hz (Auto-sensing)
Nominal Input Voltage
120 VAC
On-Battery Output Voltage
120 VAC ± 8 %
On-Battery Output Frequency
50 Hz / 60 Hz ± 1 %
Transfer Time
8 ms Typical
Max. Load for UPS Outlets
600 VA / 360 W
800 VA/450 W