AMAREW® BATTERY CHARGER USER MANUAL
6
Battery types and settings
To select charging mode or re-set during charging.
Fault
Lights in case of short circuit, reverse polarity or bad battery condition.
Battery repairing.
Battery is being charged.
Battery is full and charger is in floating mode to maintain battery in full charged status.
Mode 14.4V/2.0A
This mode is normally used for 12V lead-acid batteries <40Ah: wet batteries, MF-batteries,
AGM-batteries and most GEL-batteries.
Mode 14.4V/15.0A
This mode is normally used for 12V lead-acid batteries <300Ah: wet batteries, MF-batteries,
AGM-batteries and most GEL-batteries.
Mode 14.4V/15.0A
This mode is normally used for 12V lithium batteries <300Ah: LiFePO4 only.
Mode 14.7V/15.0A
This setting is recommended for batteries at temperatures below 5°C. It is also recommended
for many AGM batteries. This setting is not recommended for maintenance charging when the
temperature at times e5°C. In this case, the 14.4V/15A mode is recommended.