background image

 

18 

 

INSTALLATION OVERVIEW 

ZERO-CLEARANCE (METAL) FIREPLACES

   

 

 

 

 

 

 

 

 

 
 
 

2” (50mm) 

Minimum

The log shelf, 

screen, and doors 

(if present) must 

be removed.

HINT:

Paint the interior of the 
fireplace with latex paint to 
prevent fireplace odors 
from entering the home.

HINT:

Close and seal the damper 
to prevent air infiltration.

Cover plate is required if chimney 

does not have suitable rain cap.

If the firebox steps down greater than 
1", place shims (plywood, tile, etc.) 
under the leveling bolts to provide 
adequate leveling.

Silicone

The surround glass extends 1"
below the base of the insert.

A Code-Conforming (jacketed, grounded) 
receptacle may be placed within the fireplace.  Do 
not place it above the fireplace insert.

Leveling Bolts

Attach the "This fireplace has been 

altered..." plate to the fireplace (use 

two screws or other suitable 

method).  You may wish to place it in 

a location where it will be covered by 

the surround glass.

Use one of the rear screws 

on the insert to secure the 

included tie-down bracket to 

the fireplace.  Once in place, 

secure the bracket to the 

fireplace floor to prevent the  

insert from tipping. Secure 

brackets to both sides.

 

There must be a minimum 1" gap between

the wall and the glass surround. Do not block

this gap with finishing materials or trim 

Содержание INSERT-26-3825-BG

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE ZECL 26 2923 BG ZECL 30 3226 BG...

Страница 2: ...FIREPLACE 4 CLEARANCES WHTN BUILT IN 5 ZECL 26 2923 BG 7 ZECL 30 3226 BG 8 ZECL 33 3624 BG 9 ZECL 39 4134 BG 10 ZECL 2939 BG 11 INSERT 26 3825 BG 12 INSERT 30 4026 BG 13 INSERT 33 4230 BG 14 ZECL 26 2...

Страница 3: ...not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage to the heater 10 To prevent a possible fire do not block air intakes...

Страница 4: ...ble for connecting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outle...

Страница 5: ...tible surface not on linoleum or carpet The minimum clearance from the top of the appliance to a mantel combustible or non combustible is 2 50 8 mm The sides and back must maintain 1 25 4mm clearance...

Страница 6: ...6...

Страница 7: ...cm 58 4 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assista...

Страница 8: ...76 5 cm 63 8 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need a...

Страница 9: ...85 7 cm 58 4 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need as...

Страница 10: ...100 6 cm 82 5 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need...

Страница 11: ...or 66 7 cm 72 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need...

Страница 12: ...69 2 cm 43 8 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need as...

Страница 13: ...ted in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your loc...

Страница 14: ...7 cm 58 4 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assis...

Страница 15: ...m 58 4 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistan...

Страница 16: ...7 cm 64 1 cm BTU 4800 This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assis...

Страница 17: ...ve the fireplace insert The surround glass extends 1 below the base of the insert Attach the This fireplace has been altered plate to the fireplace use two screws or other suitable method You may wish...

Страница 18: ...extends 1 below the base of the insert A Code Conforming jacketed grounded receptacle may be placed within the fireplace Do not place it above the fireplace insert Leveling Bolts Attach the This fire...

Страница 19: ...electrically connected and grounded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70...

Страница 20: ...crews both hand side to take off the front glass The log is shipped in place The log has tabs on each side that hold it secure There are two screws to fix the side panel Unscrew the screws to remove t...

Страница 21: ...e as much heat output as in the High heat setting however the low setting will not require as much electrical power to operate To avoid overloading a circuit do not plug the fireplace into a circuit t...

Страница 22: ...lace flame and tray light ON OFF It has functions of setting memory DISPLAY BLUE button Adjust the blue color brightness of flame and tray DISPLAY YELLOW button Adjust the yellow color brightness of f...

Страница 23: ...mostat prior to installing the fireplace WALL THERMOSTAT WIRING 24 VAC Install Wall Thermostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove...

Страница 24: ...6 301506 301506 301506 301506 REMOTE RECEIVER 1 8 385010D ZECL 386009D INSERT 387010D ZECL 388009D INSERT 389005D 391010D 392010D FLAME EFFECT BLACK PLASTIC GLASS 1 9 601136B 601136B 601137B 601136B 6...

Страница 25: ...25 EXPLODED VIEW...

Страница 26: ...se has blown Replace the fuse Appliance is not plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off...

Страница 27: ...27 SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES...

Страница 28: ...28...

Отзывы: