10
Problem
Possible Cause
Action
Motor will not start.
No Power.
Check power supply and connection.
Interlock not depressed.
Depress interlock before activating control lever.
Defective switch / bad connection.
Contact an authorized American Sanders Dealer.
Motor fails to start /
runs sluggish.
Low voltage from excessive length or
undersized extension cord.
Use a 12 Ga. extension cord, not to exceed 50 feet (15m) length.
Defective start capacitor.
Contact an authorized American Sanders Dealer.
Defective start switch.
Contact an authorized American Sanders Dealer.
Defective run capacitor.
Contact an authorized American Sanders Dealer.
Defective motor.
Contact an authorized American Sanders Dealer.
Fuse / circuit breaker
repeatedly trips.
Low voltage.
Eliminate extension cord.
Locate power source closer to work site.
Have voltage checked by a qualified electrician.
Bad connection.
Contact an authorized American Sanders Dealer.
Defective motor.
Contact an authorized American Sanders Dealer.
Troubleshooting
Section - A
English - EN
Содержание 07076B
Страница 1: ...Orbital Sander OBS 18 Operator s Manual Original Instructions ...
Страница 27: ...Electrical Schematic 230V 50Hz 2100 Highway 265 Springdale AR USA 72764 8711 27 Parts Manual Section D ...
Страница 30: ...RF064000 063016 1 15 4 11 5 3 2 9 13 8 12 7 10 Motor Assembly Standard 30 Section D Parts Manual ...
Страница 40: ...07083A Serial Tag Section D Parts Manual 40 ...
Страница 43: ......