RSC24C2*/ CA30F*A/.053 Ori
fi
ce
Conditions: 80ºF DB 67ºF WB @ 600 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
24,402
17,221
7,181
2,041
80°
24,112
17,230
6,881
2,104
85°
23,821
17,239
6,582
2,168
90°
23,531
17,300
6,231
2,458
95°
23,240
17,360.28
5,880
2,280
100°
22,659
17,239
5,420
2,328
105°
22,078
17,117
4,961
2,375
110°
21,265
16,553
4,712
2,416
115°
20,451
15,989
4,462
2,458
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
21,535
18,021
3,514
2,227
RSC30C2*/ CA36F*A/.060 Ori
fi
ce
Conditions: 80ºF DB 67ºF WB @ 0,800 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
30,895
21,512
9,383
2,590
80°
30,527
21,523
9,005
2,671
85°
30,160
21,534
8,626
2,752
90°
29,792
21,610
8,182
2,937
95°
29,424
21,685
7,739
3,121
100°
28,688
21,534
7,155
3,069
105°
27,953
21,382
6,571
3,017
110°
26,923
20,677
6,246
3,069
115°
25,893
19,972
5,921
3,121
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
21,535
17,780
3,755
2,827
RSC36C2*
Conditions: 80ºF DB 67ºF WB @ 1,050 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
36,663
24,801
11,862
3,033
80°
36,226
24,813
11,413
3,125
85°
35,790
24,826
10,964
3,218
90°
35,353
24,913
10,440
3,429
95°
34,917
25,001
9,916
3,639
100°
34,044
24,826
9,219
3,580
105°
33,171
24,651
8,521
3,520
110°
31,949
23,838
8,111
3,580
115°
30,727
23,026
7,701
3,639
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
32,355
25,241
7,115
2,827
RSC42C2*/ CA42F*A/.069 Ori
fi
ce
Conditions: 80ºF DB 67ºF WB @ 1,220 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
43,378
29,507
13,871
3,584
80°
42,861
29,522
13,340
3,691
85°
42,345
29,536
12,808
3,799
90°
41,828
29,641
12,188
4,044
95°
41,312
29,745
11,567
4,290
100°
40,279
29,536
10,743
4,220
105°
39,246
29,328
9,918
4,150
110°
37,800
28,362
9,439
4,220
115°
36,355
27,395
8,960
4,290
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
38,281
30,877
7,405
3,899
RSC48C2*/ CA57F*A/.078 Ori
fi
ce
Conditions:
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
48,317
32,501
15,816
3,984
80°
47,742
32,518
15,224
4,103
85°
47,166
32,534
14,632
4,222
90°
46,591
32,649
13,942
4,493
95°
46,016
32,763
13,253
4,764
100°
44,866
32,534
9,462
4,687
105°
43,715
32,305
5,671
4,610
110°
42,105
31,240
5,380
4,687
115°
40,494
30,175
5,089
4,764
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
42,640
34,010
8,630
4,333
RSC60C2*/ CA60F*A/.086 Ori
fi
ce
Conditions: 80ºF DB 67ºF WB @ 1,550 CFM
Outdoor
Temp. ° F.
Total
Btuh
Sensible
Btuh
Latent
Btuh
Total
Watts
75°
60,440
39,286
21,154
5,140
80°
59,721
39,306
20,415
5,304
85°
59,001
39,325
19,676
5,469
90°
58,282
39,464
18,817
5,844
95°
57,562
39,603
17,959
6,219
100°
56,123
39,325
16,798
6,112
105°
54,684
39,048
15,636
6,006
110°
52,669
37,761
14,908
6,112
115°
50,655
36,474
14,181
6,219
TVA Conditions @ 95° OD DB, 75° ID DB, 63 ID WB
95°
53,339
41,110
12,229
5,622
Speci
fi
cation Sheet
www.amana-hac.com
5
Cooling Speci
fi
cations