Air Conditioning
Heating
Built Better Than It Has To Be
Standard Features
• Bi-Flow Liquid Line Filter-Drier (Shipped Loose)
• Front Seating Service Valves
• Scroll Compressor
• Compressor Sound Blanket
• 5-Minute Anti-Short Cycle Protection
• Automatic Reset High Pressure Switch
• Automatic Reset Loss Of Charge Switch
• Time/Temperature Defrost
• Heating Mode Thermostatic Expansion Valve (TXV)
with Internal Check Valve
• Eight-Pole Condenser Fan Motor
• Charge Compensator
Accessories
• Fossil Fuel Kit
• Ambient Temperature Kit
• Hard Start Kit
• Freeze Protection Kit
NOTE:
For optimum efficiency, units are rated only with
TXV on indoor coil.
Heat Pump Performance Data
For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual.
March 2001
20283812
Above information is for nominal CFM and 70° F indoor dry bulb.
All pressures are PSIG.
All temperatures are °F.
RHF36A2A
14/15 SEER Remote Heat Pump
Specification Sheet
Due to policy of continual product improvement, the right is reserved to
change specifications and design without notice.
NOTE:
It is important to electrically connect the unit and
properly size fuses/circuit breakers and wires in accordance
with all national and/or local electrical codes. Use copper wire
only.
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
∆
T
34
33
31
29
27
27
25
23
22
20
19
18
17
15
13
12
10
8
Amps
14.7 13.6 12.7 11.9 11.5 11.3 10.6 10.1
9.6
9.2 8.8 8.6 8.4 8.0 7.5 7.0 6.5 5.8
HI PR
261
250
241
230
225 221 212
203
195 186 179 174 171 165 158 152 147 141
LO PR
81
75
70
65
61
59
54
48
43
39
34
32
31
26
22
19
16
13
RHF36A2A / CHA42TCC / BBA48A2A
Outdoor Ambient Temperature (°F)
Cooling Capacity, BTUH (Nominal)
36,000
Compressor
R.L. Amps
16.4
L.R. Amps
83.0
Condenser Fan Motor
Horsepower
1/6
R.L. Amps
1.1
L.R. Amps
1.9
Liquid Line, Inches O.D.
3/8
Suction Line, Inches O.D.
7/8
Refrigerant Charge (oz.)
243
5.0
Power Supply (volts)
208/230-60-1
Min Circuit Ampacity
25.0
Max Overcurrent Device (amps)
45
Power Supply (in.)
1/2 or 3/4
Low Voltage (in.)
1/2
293
Specifications
Design Subcooling Cooling Mode (°F)
Electric Conduit Size
Approximate Shipping Weight (lbs)
Amana
1810 Wilson Parkway • Fayetteville, TN 37334