Amana PHWT-A100C Скачать руководство пользователя страница 3

B (top two)

O (lower two)

HP (right two)

CON (left two)

HP (right two)

CON (left two)

7) WIRING DIAGRAMS

• 

HP/CON Option

 = “HP” position (default) is for heat 

pumps, and bridges Y and W1 terminals together.  

When set to “CON” the Y and W1 terminals operate 

independently for conventional systems.

• 

B/O Option

 = “B” setting (default) means the 

shared B/O terminal is energized while in Heat 

mode and off in Cool. “O” setting means the 

shared B/O terminal is energized while in Cool 

mode and off in Heat.

Back of thermostat circuit board

Back of thermostat circuit board

WIRING DIAGRAM NOTES:

For systems that only have one fan speed (only a single 

“G” fan wire present), add a jumper wire (installer 

provided) to bridge together “GH” and “GL”.  Connect 

your fan wire to either terminal after jumper wire has 

been added.
For Conventional (cooling) applications, the options 

below can be left per the factory defaults.

WIRING DIAGRAM NOTES:

For systems that only have one fan speed (only a single 

“G” fan wire present), add a jumper wire (installer 

provided) to bridge together “GH” and “GL”.  Connect 

your fan wire to either terminal after jumper wire has 

been added.
For Heat Pump applications, the options below will 

need to be adjusted or confirmed during the install.

B/O

R

Y

W

GH

GL

C

NOT USED

A/C Cooling

Blower Fan (High Speed)

Blower Fan (Low Speed)

AMANA PHWT-A100C

THERMOSTAT

24V Power

He

ating

24V Common

B/O

R

Y

W

GH

GL

C

HP Reversing Valve

Heat Pump Compressor

Blower Fan (High Speed)

Blower Fan (Low Speed)

AMANA PHWT-A100C

THERMOSTAT

24V Power

NOT USED*  

WHEN USED FOR 

HEAT PUMP, THE Y & W 

TERMINALS ACT AS ONE

24V Common

UP TO 1H/1C CONVENTIONAL APPLICATIONS:

(AMANA PTC PTAC MODELS)

UP TO 1H/1C HEAT PUMP APPLICATIONS:

(AMANA PTH & HEH PTAC MODELS):