7
VOLTAGE MEASUREMENTS
Before connecting the unit, measure the supply voltage.
Voltage must fall within the voltage utilization range given in
Table 1.
Operating Voltage
Unit Voltage
Voltage Utilization Range
Rating
Minimum
Maximum
230/208
197
253
115
103
126
Table 1
Operating Voltage
Unit Operation
COOLING MODELS - PBC
Figure 6
Two rotary knobs (Figure 6) control temperature and opera-
tional modes. They are located to the top left of the cabinet
front.
THERMOSTAT SETTING
COOLER
CO
OL
E
R
W
A
M
ER
R
The thermostat controls the room temperature by turning
either the compressor or electric heater on and off while the
fan is running. Turn the thermostat control clockwise to
provide a cooler room temperature; turn it counterclockwise
to provide a warmer one.
NOTE
: If the fan cycle switch (see Additional Control Inputs)
is in the CYCLE mode, both the compressor and fan will
cycle on and off during the cooling modes.
Wait 3 minutes to restart
WARMER
COOLER
10
9
8
7
6
5
4
3
2
1
OFF
HIGH
COOL
Fan Only
LOW
COOL
HIGH COOL
This setting provides the most cooling output at the highest
efficiency possible. In this mode the fan runs on high and the
compressor cycles on and off.
Wait 3 minutes to restart
WARMER
COOLER
10
9
8
7
6
5
4
3
2
1
OFF
HIGH
COOL
Fan Only
LOW
COOL
LOW COOL
This setting dehumidifies the air and provides the quietest fan
operation. In this mode the fan runs at the lowest speed and
the compressor cycles on and off.
HEAT PUMP MODELS - PBE & PBH
Figure 7
Wait 3 minutes to restart
85°
WARMER
OFF
HIGH
COOL
Fan Only
LOW
COOL
HIGH
HEAT
LOW
HEAT
55°
COOLER
70°
HIGH HEAT
On high heat, the fan runs at its highest speed. In this mode
the electric heater cycles on and off by thermostat.