PRODUCT IDENTIFICATION

2

The model number is used for positive identification of component parts used in manufacturing.  Please use this number
when requesting service or parts information.

WARNING

WARNING

HIGH VOLTAGE!

Disconnect ALL power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal
injury or death.

Goodman will not be responsible
for any injury or property damage

arising from improper service or service procedures. If
you install or perform service on this unit, you assume
responsibility for any personal injury or property damage
which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.

WARNING

WARNING

ONLY individuals meeting (at a
minimum) the requirements of

an "Entry Level Technician" as specified by the Air-
Conditioning, Heating, and Refrigeration Institute (AHRI)
may use this information.  Attempting to install or repair
this unit without such background may result in product
damage, personal injury, or death.

WARNING

WARNING

    PBC    09     3  E     35  A  X  

  A A

BASIC MODEL TYPE

MAJOR/MINOR DESIGN REV.

PBC = Standard Cooler TTW
PBE = Electric Heat TTW
PBH = Heat Pump TTW

COOLING CAPACITY

09 = 9000 BTUH

12 = 12000 BTUH

RATED VOLTAGE

2 = 115V 60Hz 1Ph
3 = 230/208V 60Hz 1Ph

DESIGN SERIES (Refrig)

A = R-22 
E = R-410A 

FEATURE CODE

MA = St

a

ndard Model R-22

HEATER SIZE

AX =  Standard Model R-410A

00 = no electric heat

BX = Standard Model R-410A

 With  Modified  Front

BB =  Standard Model R-410A

35 =  3.5 kw (230/208V)

 With  Display  Remote

Use  up  to 4 as needed
In alphabetical order

Содержание PBC092E00AX

Страница 1: ...TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any...

Страница 2: ...ervice heating and air conditioning equipment WARNING WARNING ONLY individuals meeting at a minimum the requirements of an Entry Level Technician as specified by the Air Conditioning Heating and Refri...

Страница 3: ...t from the use of such non approved devices WARNING WARNING To prevent the risk of property damage personal injury or death do not store combustible materials or use gasoline or other flammable liquid...

Страница 4: ...plate located behind front grille Elec trical outlet must be close enough to unit for power cord to reach without strain Air conditioner should be the only appliance on individual circuit For personal...

Страница 5: ...et 6 feet 6 feet Dehumidification pints hour 41 oz hr 55 oz hr 41 oz hr 55 oz hr Fan Speeds CFM cooling High Low 275 275 275 275 Fan Only Speed 3 Speed 3 Speed 3 Speed 3 Speed Controls Thermostat temp...

Страница 6: ...oor 123 Outdoor 123 Outdoor Plug Type Perpendicular Perpendicular Power Cord Rating 20 amp 20 amp Power Cord Type LCDI LCDI Power Cord length 6 feet 6 feet Dehumidification pints hr 41 oz hr 55 oz hr...

Страница 7: ...an Watts Outdoor 123 Outdoor 123 Outdoor 123 Outdoor Plug Type Parallel Perpendicular Perpendicular Power Cord Rating 15 amp 20amp 20amp Power Cord Type LCDI LCDI LCDI Power Cord length 8 feet 6 feet...

Страница 8: ...48 85 10765 6140 57 10190 5930 58 9575 5710 60 8940 5485 61 75 11175 11175 100 10535 8370 79 9810 8035 82 8770 7645 87 61 80 11130 10140 91 10495 9825 94 9750 9465 97 8875 9055 102 85 11410 11410 100...

Страница 9: ...8795 4090 47 85 10465 5840 56 9890 5630 57 9275 5410 58 8640 5185 60 75 10775 10775 100 10135 7970 79 9410 7635 81 8370 7245 87 61 80 10730 9740 91 10095 9425 93 9350 9065 97 8475 8655 102 85 11010 11...

Страница 10: ...48 85 10765 6140 57 10190 5930 58 9575 5710 60 8940 5485 61 75 11175 11175 100 10535 8370 79 9810 8035 82 8770 7645 87 61 80 11130 10140 91 10495 9825 94 9750 9465 97 8875 9055 102 85 11410 11410 100...

Страница 11: ...8795 4090 47 85 10465 5840 56 9890 5630 57 9275 5410 58 8640 5185 60 75 10775 10775 100 10135 7970 79 9410 7635 81 8370 7245 87 61 80 10730 9740 91 10095 9425 93 9350 9065 97 8475 8655 102 85 11010 1...

Страница 12: ...620 5105 53 9160 4975 54 8560 4700 55 7985 4600 58 67 80 9505 6090 64 9000 5860 65 8450 5685 67 7875 5370 68 85 9345 7285 78 8910 7145 80 8295 6870 83 7720 6600 85 75 10810 3875 36 10250 3665 36 9650...

Страница 13: ...4250 48 85 10545 5930 56 9975 5720 57 9365 5500 59 8735 5275 60 75 10890 8450 78 10265 8155 79 9560 7830 82 8720 7450 85 61 80 10850 9880 91 10230 9575 94 9500 9225 97 8825 8825 100 85 11120 11120 100...

Страница 14: ...5 8590 3950 46 85 10245 5630 55 9675 5420 56 9065 5200 57 8435 4975 59 75 10490 8050 77 9865 7755 79 9160 7430 81 8320 7050 85 61 80 10450 9480 91 9830 9175 93 9100 8825 97 8425 8425 100 85 10720 1072...

Страница 15: ...TIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change always refer to the wiring diagram on the unit for the most up to dat...

Страница 16: ...MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH Wiring is subject to change always refer to the wiring diagram on the unit for the most up to...

Страница 17: ...TIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH PBH E35 A B Wiring is subject to change always refer to the wiring diagram on the unit for the mo...

Страница 18: ...connect the thermostat 2 F2 Outdoor ambient thermostat not registering on the board Replace or re connect the thermostat 3 F4 Outdoor coil thermostat not rgistering on the board Replace or re connect...

Отзывы: