You will need:

n

 

A water heater set to 120° F (49° C).

n

 

A grounded electrical outlet located within 4 ft (1.2 m) of 

power cord on back of washer.

n

 

Hot and cold water faucets located within 3 ft (0.9 m) of hot  

and cold water fill valves on washer, and water pressure  

of 20-100 psi (138-690 kPa).

n

 

A level floor with maximum slope of 1" (25 mm) under entire 

washer. Installing on carpet is not recommended.

n

 

Floor must support washer’s total weight (with water and load)  

of 315 lbs (143 kgs).

IMPORTANT:

 Do not install, store, or operate washer where it will  

be exposed to weather or in temperatures below 32° F (0° C).  

Water remaining in washer after use may cause damage in low 

temperatures. See “Washer Care” in your Use and Care Guide  

for winterizing information.

Proper installation is your responsibility.

Recessed area or closet installation

Dimensions show recommended spacing allowed, except for 

closet door ventilation openings which are minimum required.  

This washer has been tested for installation with spacing of  

0" (0 mm) clearance on the sides. Consider allowing more space 

for ease of installation and servicing, and spacing for companion 

appliances and clearances for walls, doors, and floor moldings. 

Add spacing of 1" (25 mm) on all sides of washer to reduce  

noise transfer. If a closet door or louvered door is installed,  

top and bottom air openings in door are required. 

3"

(76 mm)

3"

(76 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

17"

(432 mm)

1"

(25 mm)

1"

(25 mm)

5"

(126 mm)

14" max.

(356 mm)

DRAIN SYSTEM

Drain system can be installed using a floor drain, wall standpipe,  

floor standpipe, or laundry tub. Select method you need.

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum 

carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe 

must be at least 39" (990 mm) high; install no higher than  

96" (2.44 m) from bottom of washer. If you must install higher 

than 96" (2.44 m), you will need a sump pump system.
It is the responsibility of the installer to install and secure the 

drain hose into the provided plumbing/drain in a manner that  

will avoid the drain hose coming out of or leaking from the 

plumbing/drain.

Wall standpipe drain system

Laundry tub drain system

Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at 

least 39" (990 mm) above floor; install no higher than 96" (2.44 m) 

from bottom of washer. 

IMPORTANT:

 To avoid siphoning, no more than 4.5" (114 mm) 

of drain hose should be inside standpipe or below the top of 

wash tub. Secure drain hose with cable tie.

Floor drain system

Floor drain system requires a Siphon Break Kit (Part Number 

285834), 2 Connector Kits (Part Number 285835), and an  

Extension Drain Hose (Part Number 285863) that may be  

purchased separately. To order, please see toll-free phone  

numbers in your Use and Care Guide. Minimum siphon break: 

28" (710 mm) from bottom of washer. (Additional hoses may  

be needed.)

Floor standpipe drain system

4.5"

(114 mm)

39"

(990 mm)

4.5"

(114 mm)

39"

(990 mm)

4.5"

(114 mm)

See requirements for floor standpipe drain system.

Содержание NTW4516FW3

Страница 1: ...4 tablissement de l aplomb de la laveuse 15 Liste de v rification pour l ach vement de l installation 16 W10240509E W10240510E SP INSTALLATION NOTES Date of purchase __________________________________...

Страница 2: ...8 m Inlet hose Black EPDM space saving 90 elbow hypro blue steel couplings 2 pack Alternate parts Not supplied with washer Your installation may require additional parts To order please refer to toll...

Страница 3: ...6 mm 3 76 mm 24 in 2 155 cm2 48 in 2 310 cm2 17 432 mm 1 25 mm 1 25 mm 5 126 mm 14 max 356 mm DRAIN SYSTEM Drain system can be installed using a floor drain wall standpipe floor standpipe or laundry t...

Страница 4: ...olt 60 Hz AC only 15 or 20 amp fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit breaker serving only this appliance be...

Страница 5: ...standpipe or lay on bottom of laundry tub Drain hose form must be used 3 Remove packing tray from tub 4 Free power cord 6 Place drain hose in standpipe 4 5 114 mm Drain hose form Remove the red plast...

Страница 6: ...NNECT INLET HOSES Washer must be connected to water faucets with new inlet hoses with flat washers not provided Do not use old hoses NOTE Both hoses must be attached and have water flowing to inlet va...

Страница 7: ...ls with metal feet use a 9 16 or 14 mm open end or adjustable wrench to turn jam nuts clockwise on feet until they are about 1 2 13 mm from the washer cabinet Then turn the leveling foot clockwise to...

Страница 8: ...ter faucets are on q Check for leaks around faucets and inlet hoses q Remove protective film from console and any tape remaining on washer q Check that washer is plugged into a grounded 3 prong outlet...