Amana NGD4500VQ Скачать руководство пользователя страница 9

9

Reverse Door Swing (Optional)

You can change your door swing from a right-side opening to a 
left-side opening, if desired.

Reversible Large Side-Swing Door

1. Place towel (A) on top of dryer to protect surface.
2. Open dryer door. Remove bottom screws from cabinet side of 

hinges (C). Loosen (do not remove) top screws from cabinet 
side of hinges.

3. Lift door until top screws in cabinet are in large part of hinge 

slot. Pull door forward off screws. Set door on top of dryer. 
Remove top screws from cabinet.

4. Use a small, flat-blade screwdriver to gently remove 4 hinge 

hole plugs (D) on left side of cabinet. Insert plugs into hinge 
holes on right-hand side of cabinet.

5. Insert screws into bottom holes on left side of cabinet. Tighten 

screws halfway. Position door so large end of door hinge slot 
is over screws. Slide door up so screws are in bottom of slots. 
Tighten screws. Insert and tighten top screws in hinges.

6. Close door and check that door strike aligns with door catch 

(B). If needed, slide door catch left or right within slot to adjust 
alignment. 

Reversible Super Wide Side-Swing Door

1. Place towel (A) on top of dryer to protect surface.

2. Open dryer door. Remove bottom screws from cabinet side of 

hinges (D). Loosen (do not remove) top screws from cabinet 
side of hinges.

3. Lift door until top screws in cabinet are in large part of hinge 

slot. Pull door forward off screws. Set door (handle side up) on 
top of dryer. Remove top screws from cabinet.

4. Remove screws attaching hinges to door.
5. Remove screws at top, bottom and side of door (4 screws). 

Holding door over towel on dryer, grasp sides of outer door 
and gently lift to separate it from inner door. Do not pry apart 
with putty knife. Do not pull on door seal or plastic door 
catches.

6. Be certain to keep cardboard spacer centered between doors. 

Reattach outer door panel to inner door panel so handle is on 
the side where hinges were just removed.

7. Attach door hinges to dryer door so that the larger hole is at 

the bottom of the hinge.     

8. Remove door strike (E) from cabinet. Use a small, flat-blade 

screwdriver to gently remove 4 hinge hole plugs (F) on left side 
of cabinet. Insert plugs into hinge holes on right side of 
cabinet.

9. Insert screws into bottom holes on left side of cabinet. Tighten 

screws halfway. Position door so large end of door hinge slot 
is over screws. Slide door up so screws are in bottom of slots. 
Tighten screws. Insert and tighten top screws in hinges.

10. Remove door strike plug (B). Insert the door strike you 

removed in Step 8 into hole and secure with screw. Insert door 
strike plug into original door strike hole and secure with screw. 

11. Close door and check that door strike aligns with door catch 

(C). If it is needed, slide door catch left or right within slot to 
adjust alignment.

A

B

C

D

A

C

B

D

F

E

Содержание NGD4500VQ

Страница 1: ...Planification du syst me d vacuation 16 Installation du syst me d vacuation 17 Installation des pieds de nivellement 17 Raccordement au gaz 18 Raccordement du conduit d vacuation 18 Mise niveau de la...

Страница 2: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Страница 3: ...12 7 cm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommend...

Страница 4: ...on IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing L...

Страница 5: ...Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling or a concealed space of a building If using an existing vent system Clean lin...

Страница 6: ...ch PlanVentSystem Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible Standard exha...

Страница 7: ...ng times and increased energy usage The Vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installatio...

Страница 8: ...st be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location 3 Open the shutoff valve...

Страница 9: ...screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove...

Страница 10: ...Temperature setting If the dryer will not start check the following Dryer is plugged into a grounded 3 prong outlet Electrical supply is connected Household fuse is intact and tight or circuit breake...

Страница 11: ...ront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient IMPORTANTES INSTRUCTIONS DE S CURIT CONSERVEZ CES INSTRUCTIONS Avant de jeter ou de ranger votre vieille s che...

Страница 12: ...la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes command s par des d tecteurs automatiques peuvent ne pas fonctionner correctement Ne pas faire fonctionne...

Страница 13: ...riqu es Titre 24 HUD partie 280 ou de la Norme canadienne des habitations pr fabriqu es CAN CSA Z240MH L installation dans une maison mobile exige Un syst me d vacuation en m tal disponible l achat ch...

Страница 14: ...t manuel individuel soit install en de de 6 pieds 1 8 m de la s cheuse et l emplacement doit tre facile atteindre pour l ouverture et la fermeture Exigences concernant le raccordement au gaz Utiliser...

Страница 15: ...vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de...

Страница 16: ...ypiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles Installations standard du conduit d vacuation l aide d un conduit m tallique rigide o...

Страница 17: ...des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les installations d vacuation du c...

Страница 18: ...z existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Ouvrir le robinet d arr t du condui...

Страница 19: ...che de la porte vers la gauche ou la droite dans son logement pour ajuster l alignement Porte r versible extra large pivotement lat ral 1 Placer une serviette A sur la s cheuse pour prot ger la surfa...

Страница 20: ...t sur la s cheuse 7 Jeter recycler tout le mat riel d emballage 8 Lire Utilisation de la s cheuse dans les Instructions pour l utilisateur de la s cheuse 9 Essuyer soigneusement l int rieur du tambour...

Отзывы: