Vent System Chart

Number of 

90° elbows

Type  

of vent

Box/louvered 

hoods

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

INSTALL VENT SYSTEM

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal 

exterior wall opening around exhaust hood.

Connect vent to exhaust hood

2.

Vent must fit over the exhaust hood. Secure vent to exhaust 

hood with 4" (102 mm) clamp. Run vent to dryer location 

using straightest path possible. Avoid 90° turns. Use clamps 

to seal all joints. Do not use duct tape, screws, or other 

fastening devices that extend into interior of vent to secure 

vent, because they can catch lint.

The Vent System Chart provides venting requirements that 

will help achieve best drying performance.

Determine vent path:

Select route that will provide straightest and most direct  

 

path outdoors.

Plan installation to use fewest number of elbows and turns.

 

When using elbows or making turns, allow as much room  

 

as possible.

Bend vent gradually to avoid kinking.

 

Use as few 90° turns as possible.

 

Determine vent length and elbows needed for best 

drying performance:

Use following Vent System Chart to determine type of vent 

 

material and hood combinations acceptable to use.

NOTE:

 Do not use vent runs longer than those specified  

in Vent System Chart. Exhaust systems longer than those 

specified will:

Shorten life of dryer.

 

Reduce performance, resulting in longer drying times  

 

and increased energy usage.

NOTE:

 Side and bottom exhaust installations have a 90° turn 

inside the dryer. To determine maximum exhaust length, add one 

90° turn to the chart.

Prepare dryer for leveling legs

1. 

To avoid damaging floor, use a large flat piece of cardboard 

from dryer carton; place under entire back edge of dryer. 

Firmly grasp dryer body (not console panel) and gently lay 

dryer down on cardboard.

INSTALL LEVELING LEGS

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.

Содержание MGDE200XW

Страница 1: ..._______________________________ NOTES CONCERNANT L INSTALLATION Table des mati res S CURIT DE LA S CHEUSE 17 EXIGENCES D INSTALLATION 19 Outillage et pi ces 19 Exigences d emplacement 20 Raccordement...

Страница 2: ...nstructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safet...

Страница 3: ...tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or a...

Страница 4: ...purchasing parts Check code requirements Some codes limit or do not permit installing dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Parts supplied al...

Страница 5: ...If slope is greater than 1 25 mm install Extended Dryer Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For garage insta...

Страница 6: ...with tested spacing of 0 0 mm clearance on sides and rear Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor...

Страница 7: ...76 mm 3 76 mm 6 152 mm 76 1930 mm 1 25 mm 1 25 mm 39 min 990 mm ELECTRIC DRYER POWER HOOKUP CANADA ONLY ELECTRICAL REQUIREMENTS WARNING Electrical Shock Hazard Plug into a grounded 4 prong outlet Fail...

Страница 8: ...s with appropriate conversion Your dryer must have the correct burner for the type of gas in your home Burner information is located on the rating plate in the door well of your dryer If this informat...

Страница 9: ...be made by a qualified technician No attempt shall be made to convert the dryer from the gas specified on the model serial rating plate for use with a different gas without consulting your gas company...

Страница 10: ...rflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 7 3 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of...

Страница 11: ...e offset elbow Periscope installation Optional exhaust installations WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructi...

Страница 12: ...ghtest and most direct path outdoors Plan installation to use fewest number of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking Us...

Страница 13: ...s must be used to connect dryer to existing gas line A recommended connection is shown Your connection may be different according to supply line type size and location A 3 8 flexible gas connector B 3...

Страница 14: ...r fill valve and tighten coupling 5 Attach other end of long hose to fill valve at bottom of dryer back panel Screw on coupling by hand until it is seated on fill valve connector Using pliers tighten...

Страница 15: ...sture sensing system to operate correctly Connect vent 1 Connect vent to exhaust outlet Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure vent is...

Страница 16: ...or repair Electric Models q Plug into a grounded outlet Gas Models q Check that gas supply is on q Check for leaks All Models q Select a Timed Dry heated cycle and start dryer Do not select Air Only...

Страница 17: ...de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous...

Страница 18: ...T L odorat ne permet pas toujours la d tection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un d tecteur de gaz homologation UL ou CSA Pour d autre information contacter le four...

Страница 19: ...au gaz Compos d tanch it des raccords filet s r sistant au gaz propane Couteau utilitaire Pi ces fournies tous les mod les Pieds de nivellement 4 Connecteur en Y Tuyau d alimentation court Tuyau d ali...

Страница 20: ...eur en Y et le tuyau court si n cessaire fournis 20 100 lb po 138 690 kPa pour un rendement optimal Un plancher de niveau ayant une pente maximale de 1 25 mm sous l ensemble de la s cheuse Si la pente...

Страница 21: ...ri re Pr voir davantage d espace pour faciliter l installation et l entretien Un espace suppl mentaire peut tre requis pour les moulures de porte et de plancher et pour les plinthes Un espace suppl me...

Страница 22: ...6764 Pour plus d informations voir la section Assistance ou service dans le Guide d utilisation et d entretien RACCORDEMENT L ALIMENTATION LECTRIQUE DE LA S CHEUSE LECTRIQUE CANADA SEULEMENT Sp cifica...

Страница 23: ...la terre et connect e par un cordon Cette s cheuse doit tre reli e la terre En cas de mauvais fonctionnement ou de panne la liaison la terre r duira le risque de choc lectrique en offrant au courant...

Страница 24: ...nnecteur obtur filetage NPT de 1 8 ou plus accessible pour le raccordement de l instrument de mesure imm diatement en amont de la connexion d alimentation en gaz de la s cheuse A Connecteur de gaz fle...

Страница 25: ...pour le nettoyage Doit tre compl tement d ploy et support dans l emplacement final de la s cheuse Enlever tout exc s de conduit pour viter tout affaissement et d formation susceptible de r duire la c...

Страница 26: ...avec des vis ou avec tout autre dispositif de serrage qui se prolonge l int rieur du conduit et o la charpie risque de s accrocher Ne pas utiliser de ruban adh sif pour conduit PLANIFICATION DU syST M...

Страница 27: ...le d former Utiliser le moins possible de changements de direction 90 D terminer la longueur du conduit et le nombre de coudes n cessaires pour une performance optimale de s chage Utiliser le tableau...

Страница 28: ...oids excessif Utiliser deux ou plus de personnes pour d placer et installer la s cheuse Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure INSTALLATION DU CIRCUIT...

Страница 29: ...obinet d arr t de la canalisation d alimentation le robinet est ouvert lorsque la manette est parall le la canalisation de gaz V rifier ensuite tous les raccordements en les badigeonnant d une solutio...

Страница 30: ...isser le raccord la main pour qu il repose sur le connecteur Terminer le serrage des raccords de deux tiers de tour suppl mentaire avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque...

Страница 31: ...UIT D VACUATION Raccorder le conduit d vacuation la bouche d vacuation 1 D placer la s cheuse son emplacement final 2 l aide d une bride de serrage de 4 102 mm relier le conduit d vacuation la bouche...

Страница 32: ...er un n cessaire de superposition num ro 8572546 Pour plus de renseignements voir a section Assistance ou Service dans le Guide d utilisation et d entretien ACHEVER L INSTALLATION LISTE DE V RIFICATIO...

Отзывы: