30
Component Testing Procedures
t
s
e
T
t
n
e
n
o
p
m
o
C
n
o
i
t
a
r
t
s
u
l
l
I
Results
Side touch panel
Continuity is indicated as 100
Ω
and
below.
1
Pad
1
2
3
4
5
6
7
8
9
0
Start
Stop/Reset
Trace
3 & 5
3 & 6
3 & 7
3 & 8
3 & 9
4 & 5
4 & 6
4 & 7
4 & 8
4 & 9
5 & 6
6 & 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Top touch panel
Removal of touch panel is required
to
perform test.
Continuity is indicated as 100
Ω
and
below.
1
Pad
Time Entry
Power Level
Stage
Program Save
Quantity
Menu
Hidden Pad
Trace
5 & 7
5 & 8
5 & 9
6 & 7
6 & 8
7 & 9
8 & 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Display board (CPI)
!
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Pin 1
Top Touch Panel
Connector
Side Touch
Panel Connector
Interlock Connector
Antenna motor
Remove all wires from terminals.
Measure resistance from:
Terminal to terminal ..............................
Approximately 12K
Ω
Refer to Parts Manual
for proper power cord
part number.
Power cord
Measure resistance of wires.
Continuity should be indicated on
each wire.
Verify polarity and grounding.
!
WARNING
Grd
A
B
V1
Function
Input to Display
Board
Test Set-Up
At Display
Board
Meter Setting
Volts DC
Probe Placement
Test points V1 Pin A
and J5 Pin Grd
Results
7 - 7.5 VDC
If voltage is present and no display is
indicated, replace display board.
If no voltage is present, check wire
harness connections and H.V. board.
Test points V1 Pin B
and J5 Pin Grd
5 - 5.5 VDC
Note: Unit must be
in Ready Mode to detect
voltage at display board
Содержание KFC2W2
Страница 3: ...1 Important Safety Information 1 ...
Страница 12: ...10 RC MRC 60 Hz Quick Start Reference Guide Sample 3 ...
Страница 21: ...19 RC MRC 60 Hz Oven Construction 4 ...
Страница 29: ...27 RC MRC 60 Hz Component Testing Procedures 7 ...
Страница 41: ...39 RC MRC 60 Hz Service Test 8 ...
Страница 47: ...45 RC MRC 60 Hz Wiring Diagrams Schematics 9 ...
Страница 48: ...46 Wiring Diagram Sample Two Tube Models 9A BBCDBCB EF7 ...
Страница 49: ...47 Schematic Sample Two Tube Models 9A BBCDBCB EF7 12719301 DANGER HIGH VOLTAGE ...
Страница 50: ...48 Wiring Diagram Sample Two Tube Models 6 G 6 9A BBCDBCB EF7 Monitor Relay Board ...
Страница 51: ...49 Schematic Sample Two Tube Models 6 G 6 9A BBCDBCB EF7 20046901 DANGER HIGH VOLTAGE Monitor Relay Board ...
Страница 52: ...50 Wiring Diagram Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Страница 53: ...51 Schematic Sample Two Tube Models 6 G 6 9A B CHBCBE C7 Single HV Transformer ...
Страница 54: ...52 Wiring Diagram Sample Three Tube Models 9A BBCDBCB EF7 ...
Страница 55: ...53 Schematic Sample Three Tube Models 9A BBCDBCB EF7 12719101 DANGER HIGH VOLTAGE ...
Страница 56: ...54 Wiring Diagram Sample Three Tube Models 01 Monitor Relay Board ...
Страница 57: ...55 Schematic Sample Three Tube Models 01 Monitor Relay Board ...
Страница 58: ... 0 12 34 56 7 8 8 9 5 8 2 9 2 www acpsolutions com ...