21
RS2240002 Rev. 1
Test Modes
Power Test (Traditional Test Method)
Test equipment required is Amana power test kit R0157397 (Fahrenheit), or
Menumaster power test kit M95D5 (Celsius).
1. Fill the plastic container to the 1000 ml. line with cool tap water.
2. Using the thermometer; stir the water, measure, and record the water temperature.
Initial water temperature should be approximately 60°F (16°C).
3. Place container on the center of the oven shelf and heat the water for
33 seconds for ovens with more than 1550 watts or 63 seconds for ovens with less than 1550 watts.
NOTE: Use a watch second hand, not the oven timer.
4. Stir the water, measure and record the temperature of the water after heating time is complete.
5. Subtract the starting water temperature (Step 2), from the ending water temperature (Step 4) to obtain the
temperature rise (DT).
6. See the Traditional Power Test Temperature Chart below.
NOTES: • The IEC-705 test method requires precision measurements and equipment. It is not practical to
perform the IEC test in the field. To convert the traditional power test results to the approximate IEC-
705 rating, take the traditional power test results and add 100 watts per magnetron for the unit being
tested.
Example: 1627
watts output using the traditional power test for model HDC18
+ 200
watts (2 magnetrons X 100 watts)
1827
Approximate IEC-705 results
• Always perform power test three times for accuracy, changing the water after each test is performed.
• Variation or errors in the test procedure will cause a variance in the temperature rise. Additional power
tests should be made if temperature rise appears marginal.
• Low line voltage will cause lower temperature rise.
Temperature Chart
ONE MINUTE, THREE SECONDS run time chart for units less than 1550 watts cooking power.
∆∆∆∆∆
T
Cooking
∆∆∆∆∆
T
Cooking
(°C)
Power Output
(°C)
Power Output
7
490
15
1050
8
560
16
1120
9
630
17
1190
10
700
18
1260
11
770
19
1330
12
840
20
1400
13
910
21
1470
14
980
22
1540
∆∆∆∆∆
T
Cooking
∆∆∆∆∆
T
Cooking
(°F)
Power Output
(°F)
Power Output
16
620
26
1007
17
659
27
1046
18
697
28
1085
19
736
29
1124
20
775
30
1162
21
814
31
1201
22
852
32
1240
23
891
33
1279
24
930
34
1317
25
969
∆∆∆∆∆
T
Cooking
∆∆∆∆∆
T
Cooking
(°F)
Power Output
(°F)
Power Output
20
1550
25
1937
21
1627
26
2015
22
1705
27
2092
23
1782
28
2170
24
1860
29
2247
∆∆∆∆∆
T
Cooking
∆∆∆∆∆
T
Cooking
(°C)
Power Output
(°C)
Power Output
11
1540
14
1960
11.5
1610
14.5
2030
12
1680
15
2100
12.5
1750
15.5
2170
13
1820
16
2240
13.5
1890
THIRTY THREE SECONDS run time chart for units more than 1550 watts cooking power.