C - 3
THE AMANA “STANDARD” ADVANTAGE
Easy Filter Access
Maintaining the unit’s effi-
ciency while saving time and
money is as easy as 1-2-3.
The filter is easily accessed for
cleaning or replacement
without removing the unit front.
All units come with factory installed power cords.
(Field Supplied)
Step 1: Open the intake grille
Step 2: Pull open the intake grille
Power Cord Plugs
250V Rating Power Cord Plugs
NEMA 6 Configuration
G
W
30 amp
277V Rating Power Cord Plugs
NEMA 7 Configuration
G
W
20 amp
15 amp
20 amp
30 amp
Power Receptacle Configuration
G
G
G
NEMA6-15R; 250V receptacle,
used on 230/208V units
NEMA6-20R; 250V receptacle,
used on 230/208V units
NEMA6-30R; 250V receptacle,
used on 230/208V units
G
W
NEMA7-20R; 277V receptacle,
used on 265V units
G
NEMA7-30R; 277V receptacle,
used on 265V units
Step 3: Press down lightly on the thumb tab
at the top of the filter and remove the filter.
Optional Accessory
Advantages and Benefits
Wall Sleeve
13-3/4" x 42" x16-1/16"
No more worries about changing out non-standard sleeves that do not accommodate the bulk of what the
industry has to offer. Amana's wall sleeve is an industry standard size of 13-3/4" deep x 42" wide x 16-1/16"
high.
(Please Note: Wall Sleeve must be ordered separately.)
C-MODEL
C-MODEL
Standard Features
Advantages and Benefits
Fan
Sampling
(SBS Routine)
Imagine a uniformly maintained temperature throughout the room without constant adjustment of the thermostat. During
the "fan-auto" mode, starting at 5 minute then increasing up to 15-minute intervals, the fan automatically samples the air
inside the room. If the air is too warm, the unit will automatically cycle into the cooling mode
without thermostat adjustment.
This feature for cooling only.
Fan Mode
Switch
Take advantage of each unit's dual options: select continuous fan operation or cycle the fan ON and OFF with
the thermostat.
Easy
to Service
& LED Diagnostics
The main components are easily serviced and there is no guessing to determine the problem with our
easy-to-read diagnostics. For example: 2 blinks indicate a blown or missing fuse while 1 blink every
5 seconds means the board is operating correctly.
This diagnostic light is visible by removing the front cover.
Available Filtered
Ventilation Air
Guest's rooms stay cleaner, longer. The ventilation air intake filters outside air to reduce dust and other airborne
material.
The control lever is hidden from occupant's view.
Zero Floor Clearance
Unit can be installed flush to the finished floor, if desired. (Some accessories do not have zero clearance).
Electronic
Temperature
Limiter
Save energy and money by avoiding the extreme settings that can occur with guest operation. The temperature
limiter allows you to adjust in-room temperature settings within any of 4 pre-programmed
ranges set by you with easy to use dip switches.
Random Restart
Avoid troublesome power surges that can damage electrical circuits. Each unit has a random restart circuit to prevent
all units from restarting at one time after power disruption. Random restart occurs in 2-4 minutes.
Compressor Restart
Delay
Extended compressor-life. The unit automatically delays any restart attempt by three minutes to allow the
refrigerant pressures time to equalize.
Reduced
Outdoor
Sound Transmission
With our STC (Sound Transmission Coefficent) rating of 27, we keep outdoor sounds out-of-doors. By installing
the optional STC30 Rating Accessory Kit, ratings can be increased to STC 30, thereby meeting or exceeding
most ratings requirements.
(Kit ordered separately.)