Amana ASD2524VE Скачать руководство пользователя страница 12

12

PERFORMANCE DATA SHEETS

Base Grille Water Filtration System

Model T1WG2L/T2RFWG2 Capacity 200 Gallons (758 Liters)

Model T1WG2/T2RFWG2 Capacity 200 Gallons (758 Liters)

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The 
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). 
Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.

Use replacement cartridge T2RFWG2, part #4396841. 
In Canada, use replacement cartridge T2RFWG2, part 
#4396841B. 2008 suggested retail price of $39.99 U.S.A./$49.99 
Canada. Prices are subject to change without notice.

Model T1WG2L: Style 1 – When the filter indicator reads 10%, 
order a new filter. When the filter indicator reads 0%, it is 
recommended that you replace the filter. 
Style 2 – When the filter indicator light changes from green to 
yellow, order a new filter. When the filter indicator light changes 
from yellow to red, it is recommended that you replace the filter. 
Style 3 – When the water filter status display changes from 
“GOOD” to “ORDER,” order a new filter. When the filter indicator 
reads “REPLACE,” it is recommended that you replace the filter.

Model T1WG2: Change the water filter cartridge every 6 months 
depending upon your usage. If the water flow to the water 
dispenser or ice maker decreases noticeably before 6 months 
have passed, replace the water filter cartridge more often. 

These contaminants are not necessarily in your water supply. 
While testing was performed under standard laboratory 
conditions, actual performance may vary.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after the 
system.

Refer to the “Assistance or Service” section for the 
Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 

Application Guidelines/Water Supply Parameters

System tested and certified by NSF International against NSF/ANSI 
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate 
Class II*; and against NSF/ANSI Standard 53 for the reduction of Mercury, 
Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran. 

Substance Reduction
Aesthetic Effects

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average % 
Reduction

Chlorine Taste/Odor
Particulate Class II

*

50% reduction
85% reduction

2.0182 mg/L
1333333 #/mL

2.0 mg/L ± 10%
At least 10,000 particles/mL

0.06 mg/L
6600 #/mL

**

0.0536 mg/L
2325 #/mL

97.03
99.51

97.34
99.83

Contaminant
Reduction

NSF Reduction 
Requirements

Average
Influent

Influent Challenge 
Concentration

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average % 
Reduction

Lead: @ pH 6.5***
Lead: @ pH 8.5***

0.010 mg/L
0.010 mg/L

0.1533 mg/L
0.1400 mg/L

0.15 mg/L ± 10%
0.15 mg/L ± 10%

0.0005 mg/L
0.0007 mg/L

0.0005 mg/L
0.0006 mg/L

99.67
99.50

99.67
99.57

Mercury: @ pH 6.5
Mercury: @ pH 8.5

0.002 mg/L
0.002 mg/L

0.0058 mg/L
0.0059 mg/L

0.006 mg/L ± 10%
0.006 mg/L ± 10%

0.0002 mg/L
0.0005 mg/L

0.0002 mg/L
0.0003 mg/L

96.54
91.57

96.54
94.92

Benzene

0.005 mg/L

0.0154 mg/L

0.015 mg/L ± 10%

0.0012 mg/L

0.0006 mg/L

92.22

96.34

O-Dichlorobenzene

0.6 mg/L

1.7571 mg/L

1.8 mg/L ± 10%

0.0250 mg/L

0.0066 mg/L

98.58

99.63

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 mg/L ± 10%

0.001 mg/L

0.001 mg/L

93.33

93.33

Carbofuran

0.04 mg/L

0.0819 mg/L

0.08 mg/L ± 10%

0.0400 mg/L

0.0213 mg/L

51.13

74.00

Water Supply
Water Pressure
Water Temperature
Service Flow Rate

City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi

*

**

***

Class II particle size: 1 um to <5 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.

® NSF is a registered trademark of NSF International.

Содержание ASD2524VE

Страница 1: ...ESHOOTING 9 ACCESSORIES 11 WATER FILTER CERTIFICATIONS 11 PERFORMANCE DATA SHEETS 12 WARRANTY 13 SÉCURITÉ DU RÉFRIGÉRATEUR 14 INSTRUCTIONS D INSTALLATION 15 UTILISATION DU RÉFRIGÉRATEUR 19 ENTRETIEN DU RÉFRIGÉRATEUR 22 DÉPANNAGE 23 ACCESSOIRES 25 FEUILLES DE DONNÉES SUR LA PERFORMANCE 26 GARANTIE 27 REFRIGERATORUSERINSTRUCTIONS W10162456A You can be killed or seriously injured if you don t immedia...

Страница 2: ...g Remove doors from your old refrigerator Use nonflammable cleaner Keep flammable materials and vapors such as gasoline away from refrigerator Use two or more people to move and install refrigerator Disconnect power before installing ice maker on ice maker kit ready models only Use a sturdy glass when dispensing ice on some models WARNING Suffocation Hazard Remove doors from your old refrigerator ...

Страница 3: ... removing a light bulb turn the control Thermostat Refrigerator or Freezer Control depending on the model to OFF and then disconnect the refrigerator from the electrical source When you are finished reconnect the refrigerator to the electrical source and reset the control Thermostat Refrigerator or Freezer Control depending on the model to the desired setting See Using the Controls Water SupplyReq...

Страница 4: ...rom the connection on the lower rear corner of refrigerator to the water pipe Add 7 ft 2 1 m to allow for cleaning Use 6 35 mm O D outside diameter copper tubing Be sure both ends of copper tubing are cut square 5 Using a cordless drill drill a 6 35 mm hole in the cold water pipe you have selected 6 Fasten the shutoff valve to the cold water pipe with the pipe clamp Be sure the outlet end is solid...

Страница 5: ...atch of ice Allow 3 days to completely fill ice container REFRIGERATOR USE UsingtheControls For your convenience your refrigerator controls are preset at the factory When you first install your refrigerator make sure that the controls are still preset The Refrigerator Control and the Freezer Control should both be set to the mid settings IMPORTANT Your product will not cool when the REFRIGERATOR C...

Страница 6: ...ruits and vegetables with skins HIGH closed for best storage of fresh leafy vegetables ChilledDoorBin onsomemodels Cool air from the freezer is directed to the refrigerator door bin directly beneath the vents NOTE The dairy compartment and can rack are not associated with the Chilled Door Bin feature Chilled Door Bin Control The chilled door bin control is located on the left hand side of the refr...

Страница 7: ...t DIM mode The dispenser light will remain on but at a lower intensity OFF Press LIGHT a third time to turn the dispenser light off The dispenser lights are LEDs that can not be changed If it appears that your dispenser lights are not working see Troubleshooting for more information The Dispenser Lock on some models The dispenser can be turned off for easy cleaning or to avoid unintentional dispen...

Страница 8: ...e the O rings are still in place after the covers are removed 6 Push the filter into the base grille The eject button will pop back out when the filter is fully engaged 7 Flush the water system See Water and Ice Dispensers REFRIGERATOR CARE Cleaning Both the refrigerator and freezer sections defrost automatically However clean both sections about once a month to avoid buildup of odors Wipe up spil...

Страница 9: ...TE Adjusting the temperature controls to coldest setting will not cool either compartment more quickly The motor seems to run too much Your new refrigerator may run longer than your old one due to its high efficiency compressor and fans The unit may run even longer if the room is warm a large food load is added doors are opened often or if the doors have been left open The refrigerator is noisy Re...

Страница 10: ... arm or switch depending on model is in the ON position New installation Wait 24 hours after ice maker installation for ice production to begin Wait 72 hours for full ice production Large amount of ice recently removed Allow 24 hours for ice maker to produce more ice Ice cube jammed in the ice maker ejector arm Remove ice from the ejector arm with a plastic utensil Reverse osmosis water filtration...

Страница 11: ... The filter may be clogged or incorrectly installed Is a reverse osmosis water filtration system connected to your cold water supply See Water Supply Requirements in either the Installation Instructions or the Use Care Guide Water is leaking from the dispenser NOTE One or two drops of water after dispensing is normal Glass not being held under the dispenser long enough Hold the glass under the dis...

Страница 12: ...afe or of unknown quality without adequate disinfection before or after the system Refer to the Assistance or Service section for the Manufacturer s name address and telephone number Refer to the Warranty section for the Manufacturer s limited warranty Application Guidelines Water Supply Parameters System tested and certified by NSF International against NSF ANSI Standard 42 for the reduction of C...

Страница 13: ...ppliance is located in a remote area where service by an authorized Amana servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined Thi...

Страница 14: ...rité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifient AVERTISSEMENT réfrigérateur prendre quelques précautions fondamenta...

Страница 15: ...e cette instruction peut causer un décès ou des lésions cérébrales AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer le réfrigérateur Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure Déplacement de votre réfrigérateur Votre réfrigérateur est lourd Lors du déplacement du réfrigérateur pour le nettoyage ou le s...

Страница 16: ... de mise à la terre Une source d alimentation de 115 volts 60 Hz type 15 ou 20 ampères CA seulement protégée par fusible et adéquatement mise à la terre est nécessaire Il est recommandé d utiliser un circuit distinct pour alimenter uniquement votre réfrigérateur Utiliser une prise murale qui ne peut pas être mise hors circuit à l aide d un commutateur Ne pas utiliser un câble de rallonge REMARQUE ...

Страница 17: ...d eau placer la commande de la machine à glaçons à la position OFF arrêt Raccordement à une canalisation d eau 1 Débrancher le réfrigérateur ou déconnecter la source de courant électrique 2 FERMER le robinet principal d arrivée d eau OUVRIR le robinet de puisage le plus proche pendant une période suffisante pour que la canalisation d eau se vide 3 Trouver une canalisation d eau froide verticale de...

Страница 18: ...a main Ensuite le serrer avec une clé deux tours de plus Ne pas serrer excessivement 4 OUVRIR le robinet d arrêt 5 Inspecter pour rechercher les fuites Serrer tous les raccords y compris les raccordements de la valve d entrée d eau ou les écrous qui coulent Style 3 1 Débrancher le réfrigérateur ou déconnecter la source de courant électrique 2 Retirer et jeter le bouchon en nylon noir du tuyau d ea...

Страница 19: ...ci dessous comme guide Attendre au moins 24 heures entre les ajustements Désactivation des signaux sonores Pour désactiver tous les signaux sonores émis par le distributeur et les commandes appuyer simultanément sur ICE glaçons et FILTER filtre pendant 3 secondes Pour réactiver tous les signaux sonores appuyer de nouveau simultanément sur ICE et FILTER pendant 3 secondes Commandedetempératuredansl...

Страница 20: ...s pour que le réfrigérateur se refroidisse et refroidisse l eau Accorder 24 heures pour produire la première quantité de glaçons Jeter les trois premières quantités de glaçons produites Le distributeur d eau IMPORTANT Puiser une quantité suffisante d eau chaque semaine pour maintenir un approvisionnement frais Distribution d eau 1 Appuyer un verre robuste contre le levier du distributeur d eau 2 R...

Страница 21: ...du bras en broche vers le haut ou vers le bas À NOTER Accorder 24 heures pour produire la première quantité de glaçons Jeter les trois premières quantités de glaçons produites La qualité de vos glaçons dépend de la qualité de l eau fournie à votre machine à glaçons Éviter de brancher la machine à glaçons à un approvisionnement d eau adoucie Les produits chimiques adoucisseurs d eau tels que le sel...

Страница 22: ... du pétrole sur les pièces en plastique les garnitures intérieures et de portes ou les joints de portes Ne pas utiliser d essuie tout tampons à récurer ou autres outils de nettoyage abrasifs 1 Débrancher le réfrigérateur ou déconnecter la source de courant électrique 2 Laver à la main rincer et sécher les pièces amovibles et les surfaces internes à fond Utiliser une éponge propre ou un linge doux ...

Страница 23: ...des bruits intermittents venant de votre nouveau réfrigérateur qui n avaient pas été décelés avec votre ancien modèle Voici une liste des sons normaux accompagnés d une explication Bourdonnement entendu lorsque le robinet d arrivée d eau s ouvre pour remplir la machine à glaçons Pulsation les ventilateurs le compresseur se règlent afin d optimiser la performance Sifflement cliquetis écoulement de ...

Страница 24: ...elle une déformation Une déformation dans la canalisation peut réduire l écoulement d eau Redresser la canalisation d eau La machine à glaçons est elle allumée S assurer que le bras de commande en broche ou l interrupteur selon le modèle est en position ON S agit il d une nouvelle installation Attendre 24 heures après l installation pour le commencement de la production de glaçons Attendre 72 heur...

Страница 25: ... canalisation d eau S agit il d une nouvelle installation Rincer et remplir le système de distribution d eau Un filtre à eau est il installé sur le réfrigérateur Le filtre peut être obstrué ou installé incorrectement Un système de filtration de l eau à osmose inverse est il connecté à votre canalisation d eau froide Voir Spécifications de l alimentation en eau soit dans les instructions d installa...

Страница 26: ...ment Ne pas utiliser pour le filtrage d une eau microbiologiquement polluée ou de qualité inconnue en l absence d un dispositif de désinfection adéquat avant ou après le système Consulter la section Assistance ou service pour obtenir le nom l adresse et le numéro de téléphone du fabricant Consulter la section Garantie pour la garantie limitée du fabricant Directives d application Paramètres d appr...

Страница 27: ... service d entretien Amana autorisé n est pas disponible 10 La dépose et la réinstallation de votre gros appareil si celui ci est installé dans un endroit inaccessible ou n est pas installé conformément aux instructions d installation fournies 11 Les gros appareils ménagers dont les numéros de série et de modèle originaux ont été enlevés modifiés ou qui ne peuvent pas être facilement identifiés La...

Страница 28: ...Trademark Trademark of Maytag Corporation or its related companies Used under license by Maytag Limited in Canada Marque déposée Marque de commerce de Maytag Corporation ou de ses compagnies affiliées Emploi sous licence par Maytag Limited au Canada 2 08 Printed in U S A Imprimé aux É U ...

Отзывы: