Amana AHQ246 Скачать руководство пользователя страница 11

11

ADDITIONAL INFORMATION

• The remote control will operate all the control panel features.

Instructions will be the same.

The “COOL” circuit has an automatic 3 minute time de-
layed start if the unit is turned off and on quickly.  This
prevents overheating of the compressor and possible cir-
cuit breaker tripping.

NOTE: The fan will continue to run during this time.

• The control will maintain any set temperature between 60°F

and 90°F (cooling), 55°F and 80°F (heating).

• The control is capable of displaying temperature in degrees

(Fahrenheit) or degrees (Celsius).  To convert from one to the
other, press and hold the UP and DOWN Temperature Selec-
tion Pads at the same time for 3 seconds.

COMPRESSOR

The compressor is hermetically sealed, permanently lubricated
and requires no additional oiling.

FRONT PANEL AND GRILLE

The front panel and grille can be cleaned with a mild soap or
detergent.  Do not use hydrocarbon-based cleaners (e.g. acetone,
benzene, naphtha, gasoline, etc.) to clean the front panel or grille.
Use care when cleaning the control area.  Do not use an exces-
sively wet cleaning cloth.

SCHEDULED MAINTENANCE

To achieve continuing top performance and high efficiency, a regular
cleaning/inspection schedule must be established.  Maintaining
this schedule can be accomplished by either a local maintenance
staff or an authorized servicer and must follow the instructions
described in this manual.

• If the unit is operated in a dusty climate, dust may collect in

the basepan and clog the condenser coil.  It is advisable to
remove the unit from the sleeve and thoroughly clean the
basepan and condenser coil on a periodic basis.

• If the unit is installed ocean side or in a corrosive atmosphere,

its life may be greatly reduced by the corrosive environment.
Under these conditions, the unit should be removed from the
sleeve and completely cleaned once a year.  At that time any
scratches or blisters on the painted surfaces should be
sanded and repainted.

OUTDOOR COIL CLEANING

The coils on the outdoor side of the air conditioner should be
checked regularly. For cleaning outside coil, remove the 6 screws
that mount the condenser coil top cover to condenser shroud.

NORMAL OPERATING SOUNDS
AND CONDITIONS

POPPING OR GURGLING SOUNDS

This sound is the refrigerant traveling through the lines.  This is a
normal sound which may be heard for a few seconds after the unit
shuts off.

WATER TRICKLING SOUNDS

This sound is produced by the water as it is picked up and run
over the coils.  This procedure improves the efficiency of the unit
and helps with water removal.

WATER DRIPPING

Water will collect in the basepan during high humidity days.

STARTING DELAY

You may notice a short delay in the startup if you try to restart the
unit too soon after turning it off or if you adjust the thermostat right
after the compressor has shut off.  This delay protects the com-
pressor.

Obtaining Service

In the unlikely event this unit requires repair or servicing beyond
what is covered in this manual, contact an authorized service or-
ganization.

To obtain an authorized servicer, contact your sales representa-
tive or agency.

Содержание AHQ246

Страница 1: ...ur responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use Safety is a matter of common sense a matter of thinking before acting Most...

Страница 2: ...available for the type power plug on the unit DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER CORD Note the types of acceptable plugs on the following figure Refer to the data serial plate for electr...

Страница 3: ...louver panel kit is required for unit installation into an existingAmana brand 26 wall sleeve ATWEAK or TWFAK adapter kit is required for unit installation into an existing 27 wall sleeve The rear lou...

Страница 4: ...ondenser fan 5 Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten locking plate screw Locking Plate Figure C 6 If outlet is on the left side of the un...

Страница 5: ...ide air discharge and reattaching screw at front Figure 4 Screw AIRDIRECTION Horizontal louvers on the front grille let you control the air direction up and down Remove the front grille to adjust the...

Страница 6: ...6 WIRING Before wiring the unit please review the following warnings and cautions...

Страница 7: ...ns The unit can be controlled by the touchpad alone or with the remote control NOTE The remote control will work normally after a 5 second reset BATTERY SIZE AAA MED HIGH LOW AUTO COOL ENERGY SAVER FA...

Страница 8: ...cannot be used when in the FAN ONLY mode YOU WILL SEE YOU WILL SEE YOU WILL SEE THE SPEED CHOSEN YOU WILL SEE TO CHANGE TEMPERATURE SETTING TO CHANGE FAN SPEEDS NOTE Tap or hold either up S or down T...

Страница 9: ...happened the above steps must be repeated again NOTE Factory default setting is for F To convert to C press the INCREASE S S S S S DECREASE T T T T T buttons simultaneously for approximately 5 seconds...

Страница 10: ...LOW AUTO COOL ENERGY SAVER FAN ONLY SPEED FAN MODE SLEEP POWER TIMER Set TEMPERATURE TIMER HEAT 72 SPEED FAN MODE SLEEP POWER TIMER Set TEMPERATURE TIMER SPEED FAN MODE SLEEP POWER TIMER Set TEMPERAT...

Страница 11: ...ct in the basepan and clog the condenser coil It is advisable to remove the unit from the sleeve and thoroughly clean the basepan and condenser coil on a periodic basis If the unit is installed ocean...

Страница 12: ...locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Goodman will not pay for electricity or fuel costs o...

Страница 13: ...defective part must be returned to an Amana brand heating and air conditioning products distributor by an authorized Amana brand servicer and all warranty service must be performed by an autho rized...

Страница 14: ...14 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 15: ...15 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 16: ...16 2010 Goodman Company L P is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company L P Houston TX All rights reserved www amana ptac com...

Отзывы: