Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.  

Do not obstruct flow of combustion and ventilation air.

 

It is the installer’s responsibility to comply with installation 

clearances specified on the model/serial rating plate. The 

model/serial rating plate is located on the left side of the 

bottom of the broiler.

A.  Model/serial rating plate location

 

The range should be located for convenient use in the 

kitchen.

 

Recessed installations must provide complete enclosure of 

the sides and rear of the range.

 

To eliminate the risk of burns or fire by reaching over heated 

surface units, cabinet storage space located above the 

surface units should be avoided. If cabinet storage is to be 

provided, the risk can be reduced by installing a range hood 

that projects horizontally a minimum of 5" (12.7 cm) beyond 

the bottom of the cabinets.

 

All openings in the wall or floor where range is to be installed 

must be sealed.

 

Do not seal the range to the side cabinets.

 

Cabinet opening dimensions that are shown must be used. 

Given dimensions are minimum clearances.

 

The anti-tip bracket must be installed. To install the anti-tip 

bracket shipped with the range, see “Install Anti-Tip Bracket” 

section.

 

Grounded electrical supply is required. See “Electrical 

Requirements” section.

 

Proper gas supply connection must be available. See “Gas 

Supply Requirements” section.

 

Contact a qualified floor covering installer to check that the 

floor covering can withstand at least 200°F (93°C).

 

Use an insulated pad or ¼" (0.64 cm) plywood under range  

if installing range over carpeting.

IMPORTANT:

 To avoid damage to your cabinets, check with 

your builder or cabinet supplier to make sure that the materials 

used will not discolor, delaminate, or sustain other damage. This 

oven has been designed in accordance with the requirements 

of UL and CSA International and complies with the maximum 

allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 

Home Construction and Safety Standard, Title 24 CFR, 

Part 3280 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD Part 280). When such 

standard is not applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A, or with local 

codes.

Mobile home installations require:

 

When this range is installed in a mobile home, it must be 

secured to the floor during transit. Any method of securing 

the range is adequate as long as it conforms to the 

standards listed above.

Product Dimensions

A.  36" (91.4 cm)
B. 29

7

8

" (75.9 cm)

C. 25

7

64

" (63.8 cm)

D. 47

5

64

" (119.6 cm)

A

B

A

C

D

Содержание AGR4230BAW

Страница 1: ...pack Range 7 Install Anti Tip Bracket 7 Make Gas Connection 8 Verify Anti Tip Bracket Is Installed and Engaged 9 Level Range 10 Electronic Ignition System 10 Complete Installation 11 GAS CONVERSIONS 12 LP Gas Conversion 12 Complete Conversion 14 Natural Gas Conversion 14 Complete Conversion 16 IMPORTANT Save for local inspector s use Installer Leave installation instructions with the homeowner Hom...

Страница 2: ... property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cann...

Страница 3: ...ket to floor Parts needed Check local codes and consult gas supplier Check existing gas supply and electrical supply See Electrical Requirements and Gas Supply Requirements sections In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of M...

Страница 4: ...ectrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 0 64 cm plywood under range if installing range over carpeting IMPORTANT To avoid damage to your cabinets check with ...

Страница 5: ...mended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker...

Страница 6: ...ce connector If local codes permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 1 3 cm or 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the rang...

Страница 7: ... range to support the range when it is laid on its back 5 Using 2 or more people firmly grasp the range and gently lay it on its back on the cardboard corners 6 Pull cardboard bottom firmly to remove then remove foam support 7 Use an adjustable wrench to loosen the leveling legs Adjust the leveling legs to the correct height Leveling legs can be loosened to add up to a maximum of 1 2 5 cm A minimu...

Страница 8: ...se with LP gas to the smaller thread ends of the flexible connector adapters see B and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters being certain not to move or turn the gas pressure regulator 3 Use a 15 16 2 4 cm combination wrench and an adjustable wrench to attach the flexible connector to ...

Страница 9: ...the broiler and grasp the lower right or left side of the control panel as shown NOTE If your countertop is mounted with a backsplash it may be necessary to grasp the range higher than is shown in the illustration 2 Slowly attempt to tilt the range forward If you encounter immediate resistance the range foot is engaged in the anti tip bracket 3 If the rear of the range lifts more than 1 3 cm off t...

Страница 10: ...p and oven burners use electronic igniters in place of standing pilots When the cooktop control knob is turned to the IGNITE position the system creates a spark to light the burner This sparking continues until the control knob is turned to the desired setting When the oven control is turned to the desired setting a hot surface igniter heats to a bright orange and ignites the gas No sparking occur...

Страница 11: ...tter screw 8 Reinstall flame spreader and oven tray Reinstall the oven racks and close oven door 9 Close the broiler door Complete Installation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See the Level Ra...

Страница 12: ... International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire WARNING...

Страница 13: ...puds using a 7 mm combination wrench A Spud B Holder NOTE The range is equipped with 3 standard burners and 1 simmer burner right rear A Standard burner LP gas orifice spud number 88 B Standard burner LP gas orifice spud number 88 C Simmer burner LP gas orifice spud number 70 Yellow White D Standard burner LP gas orifice spud number 88 5 Place the Natural gas orifice spuds in the parts bag for fut...

Страница 14: ...very distinct blue flame to 0 64 cm to 1 3 cm long The outer cone is not as distinct as the inner cone LP gas flames have a slightly yellow tip 4 Close the broiler door and turn the knob to OFF position 5 Refer to the Complete Installation section to complete this procedure Natural Gas Conversion 1 Turn manual shut off valve to the CLOSED position A Gas supply line B Manual shut off valve closed p...

Страница 15: ...uds are stamped 149 and one is stamped 110 Red Brass 3 Remove the LP gas orifice spuds using a 7 mm combination wrench 4 Install the Natural gas orifice spuds using a 7 mm combination wrench A Spud B Holder NOTE The range is equipped with 3 standard burners and 1 simmer burner right rear A Standard burner Natural gas orifice spud number 149 B Standard burner Natural gas orifice spud number 149 C S...

Страница 16: ...ntaining literature 7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn the manual shut off valve in the gas supply line to the open position 3 Refer to the Electronic Ignition System section for proper burner ingestion operation and burner flame adjustm...