background image

4

Product Dimensions

IMPORTANT: Range must be level after installation. Follow the 
instructions in the “Level Range” section. Using the cooktop as a 
reference for leveling the range is not recommended.

*Range can be raised approximately 1" (2.5 cm) by adjusting 

the leveling legs.

**Front of door and drawer may extend further forward 

depending on styling.

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.

A freestanding range may be installed next to combustible walls 
with zero clearance.

*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 

cabinet is covered by not less than 

¹⁄₄

" (0.64 cm) flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the 
cooking platform and the bottom of an uncovered wood or metal 
cabinet.

A. 27

³⁄₄

" (70.5 cm) max. depth with handle

B. 46

⁷⁄₈

" (119.1 cm) overall height (max.) with leveling legs 

screwed all the way in*

C. 36" (91.4 cm) cooktop height (max.) with leveling legs screwed 

all the way in*

D. 29

⁷⁄₈

" (75.9 cm) width

E. 25

⁵⁄₁₆

" (64.3 cm) depth - back of range to front of cooktop**

F. Model/serial rating plate (located on the frame behind a top 

corner of the door or either side of the drawer)

A

B

C

D

E

F

A. 13" (33.0 cm) max. upper cabinet depth
B. 30" (76.2 cm) min. opening width

C. For minimum clearance to top of cooktop, see NOTE*
D. 30

¹⁄₈

" (76.5 cm) min. opening width

E. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,

5

¹⁄₂

" (14.0 cm) max. from floor

F. Cabinet door or hinges should not extend into the cutout

A

B

D

F

E

C

Содержание AER5630BAS

Страница 1: ...quirements U S A Only 5 INSTALLATION INSTRUCTIONS 6 Unpack Range 6 Install Anti Tip Bracket 6 Electrical Connection U S A Only 8 Verify Anti Tip Bracket Is Installed and Engaged 12 Level Range 13 Warm...

Страница 2: ...the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING Tip Over Hazard A child or adult can tip the range and be killed Install...

Страница 3: ...ntally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The anti tip bracket must be installed To...

Страница 4: ...en bottom of wood or metal cabinet is covered by not less than 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or...

Страница 5: ...llic sheathed copper or aluminum cable See the Electrical Connection U S A Only section Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever nece...

Страница 6: ...e installing the range in a mobile home you must secure the range to the floor 3 Determine and mark centerline of the cutout space The mounting can be installed on either the left side or right side o...

Страница 7: ...llow for final electrical connections Remove shipping base cardboard or hardboard from under range 7 Move range into its final location making sure rear leveling leg slides into anti tip bracket 8 Mov...

Страница 8: ...ening Tighten strain relief screw against the power supply cord Power Supply Cord Direct Wire WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug...

Страница 9: ...und link under the screw 3 Feed the power supply cord through the strain relief on the cord conduit plate on bottom of range Allow enough slack to easily attach the wiring to the terminal block A Remo...

Страница 10: ...the outer terminal block posts with 10 32 hex nuts 4 Securely tighten hex nuts NOTE For power supply cord replacement use only a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked...

Страница 11: ...t the neutral white wire to the center terminal block post with one of the 10 32 hex nuts 7 Connect line 2 red and line 1 black wires to the outer terminal block posts with 10 32 hex nuts 8 Securely t...

Страница 12: ...attempt to tilt the range forward If you encounter immediate resistance the range foot is engaged in the anti tip bracket 3 If the rear of the range lifts more than 1 3 cm off the floor without resist...

Страница 13: ...veling legs up or down until the range is level Push range back into position Check that rear leveling leg is engaged in the anti tip bracket Style 2 Ranges Equipped with a Warming Drawer or Premium S...

Страница 14: ...tion Check that the door is free to open and close If it is not repeat the removal and installation procedures CompleteInstallation 1 Check that all parts are now installed If there is an extra part g...

Страница 15: ...ce 4 Check that the anti tip bracket is installed and engaged See the Verify Anti Tip Bracket Is Installed and Engaged section 5 Check that range is level 6 Reconnect power WARNING Tip Over Hazard A c...

Страница 16: ...W10403811C 2012 Whirlpool All rights reserved 8 12 Printed in U S A...

Отзывы: