Amana ae series Скачать руководство пользователя страница 8

8

Wait 3 minutes to restart

85°

WARMER

OFF

HIGH

COOL

Fan Only

LOW

COOL

HIGH

HEAT

LOW

HEAT

55°

COOLER

70°

LOW HEAT

On low heat, the fan runs at its lowest speed and provides the
quietest fan operation.  In this mode the electric heater
cycles on and off by thermostat.

Wait 3 minutes to restart

85°

WARMER

OFF

HIGH

COOL

Fan Only

LOW

COOL

HIGH

HEAT

LOW

HEAT

55°

COOLER

70°

FAN ONLY

This setting circulates air.  If the exhaust air option is used,
this setting  will exhaust stale indoor air.  In this mode, the
fan runs continuously at high speed without compressor
operation.

HEAT PUMP MODELS  -  PBE & PBH

Figure 8

When the outdoor temperature is lower than 25°F, heat is
provided by the electric heater in the air conditioner instead
of by the heat pump.

ADDITIONAL CONTROL INPUTS

NOTE:

  Not available on all models.

Fan Cycle Switch

The fan cycle switch is located behind the plastic front
assembly underneath the control knob (Figure 9).  The fan
cycle switch sets the operational mode of the fan.  In the
NORMAL position, the fan will run continuously whenever
the unit is in the heat or cool mode.  In the CYCLE position,
the fan will cycle on and off with the compressor when the unit
is in the cool mode.  This switch can only be set by a servicer.

FAN CYCLE

SWITCH

Figure 9

Preventative Maintenance

WARNING

To prevent death or personal injury due to
electrical shock, unplug the unit at the wall
outlet or turn off power at the fuse box or
circuit breaker before servicing the unit.

INTAKE AIR FILTER

The intake air filter should be cleaned when it is dirty or at
least once a month.  The intake air filter is constructed of
durable polypropylene.

The following procedure is used to remove the intake filter:

1. Remove the filter by lifting up on filter handle. See Figure

A.

2. Remove intake air filter from front panel.

3. Clean filter with a vacuum or running water.  If using

water, please be sure that the filter is not excessively
wet when replaced.

4. Reverse this procedure to reinstall the filter.

Содержание ae series

Страница 1: ...n its safe use Safety is a matter of common sense a matter of thinking before acting Most dealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual areintendedassupplementaltoexistingpractices However ifthereisadirectconflictbetweenexisting practices and the content of this manual the precautions listed here take precedence RECOGNIZE THIS ...

Страница 2: ...ck upperstyrofoam shipping blocks and styrofoam corner posts 3 Remove the front assembly 4 Lift the unit from the remaining carton 5 Disposeofthecardboardandstyrofoamatanapproved Recycle Center Check all contents for damaged or missing parts In case of concealed damage notify the carrier as soon as possible preferably within 5 days Refer to step 3 of the Transportation Damage section if damage or ...

Страница 3: ...KGSLV rear louver panel kit is required for unit installationintoanexistingAmana brand26 wallsleeve A TWEAK2 or TWFAK2 adapter kit is required for unit instal lation into an existing 27 wall sleeve The rear louver panel directs air flow for proper unit operation and protects the outdoorcoil Thepanelmustbeinstalledbeforeinstallingthe chassis These kits are not supplied with the unit Refer to the In...

Страница 4: ...chassis into the sleeve Ensure thatthegroundwireisnotpinchedorinthepathofthe condenserfan 5 Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten locking plate screw Locking Plate Figure C 6 If outlet is on the left side of the unit route power cord as shown in Figure D Clamp Power Cord Figure D ...

Страница 5: ...lbecirculatedandconditioned When set at OPEN some inside air is exhausted outside Locating Hole Locating Hole Screw Hole Screw Hole OPEN position Mesh end toward back CLOSE position Mesh end toward front Figure E To open or close the vent 1 Removethefrontgrille 2 Remove the vent card screw 3 Remove the vent card turn it over and replace it by locating rear hole in card over locating pin inside air...

Страница 6: ...arnings and cautions WARNING To avoid the risk of electrical shock personal injury or death do not service this unit without first opening all disconnects and or removing the unit cord set plug from the wall outlet WARNING To avoid the risk of electrical shock personal injury or property damage do not use an extension cord with this unit WARNING To avoid the risk of fire property damage or persona...

Страница 7: ...rovide a warmer one NOTE Ifthefancycleswitch seeAdditionalControlInputs is in the CYCLE mode both the compressor and fan will cycle on and off during the cooling modes Wait3minutestorestart WARMER COOLER 10 9 8 7 6 5 4 3 2 1 OFF HIGH COOL Fan Only LOW COOL HIGH COOL This setting provides the most cooling output at the highest efficiencypossible Inthismodethefanrunsonhighandthe compressor cycles on...

Страница 8: ...assembly underneath the control knob Figure 9 The fan cycle switch sets the operational mode of the fan In the NORMAL position the fan will run continuously whenever the unit is in the heat or cool mode In the CYCLE position thefanwillcycleonandoffwiththecompressorwhentheunit isinthecoolmode Thisswitchcanonlybesetbyaservicer FAN CYCLE SWITCH Figure 9 PreventativeMaintenance WARNING To prevent deat...

Страница 9: ...itions theunit should be removed from the sleeve and completely cleaned once a year At that time any scratches or blisters on the painted surfaces should be sanded and repainted OUTDOORCOILCLEANING Thecoilsontheoutdoorsideoftheairconditionershouldbe checked regularly For cleaning outside coil remove the 6 screwsthatmountthecondensercoiltopcovertocondenser shroud NormalOperatingSoundsandConditions ...

Страница 10: ...W RRGPDQ RQVXPHU IIDLUV DW WKH QXPEHU RU DGGUHVV ORFDWHG DW WKH ERWWRP RI WKLV FHUWLILFDWH RU ZDUUDQW FUHGLW WKH GHIHFWLYH SDUW PXVW EH UHWXUQHG WR DQ PDQD KHDWLQJ DQG DLU FRQGLWLRQLQJ SURGXFWV GLVWULEXWRU E DQ DXWKRUL HG PDQD EUDQG VHUYLFHU Q SDUW UHSODFHG RU OHDN UHSDLUHG SXUVXDQW WR WKLV ZDUUDQW LV ZDUUDQWHG RQO IRU WKH XQH SLUHG SRUWLRQ RI WKH ZDUUDQW WHUP DSSO LQJ WR WKH RULJLQDO SDUW 7KHVH Z...