Amana Technical Information
—
Room Air Conditioner
December 2002
16022064
(Replaces RT4110056 Rev. 0)
1
AAC101SRA
PAAC101SRA0
•
Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this air conditioner.
•
Refer to Service Manual 16022061 for installation, operation, disassembly, testing, and troubleshooting
information.
•
Refer to Parts Reference material for part number information.
CAUTION
!
All safety information must be followed as provided in Service Manual 16022061.
!
WARNING
To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge
capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during
disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Model
AAC101SRA
Electrical requirements
115 VAC 60Hz
Refrigerant/amount
R22/30 ounces
Compressor
Voltage low/high (nominal)
BTUH
98/132 VAC (115 VAC)
10,735 BTUH
Watts
1000 watts
Current
Lock rotor
Full load
54 amps
8.8 amps
Overload protector
External
Fan motor
Electrical requirements
RPM
Low speed
Med speed
High speed
Watts at high speed
Current at high speed
115 VAC 60Hz
730 RPM
830 RPM
1000 RPM
97 watts
2.1 amps
Compressor Capacitor
Capacitance
Voltage rating (nominal)
45 Mfd ±10%
250 V
Fan Motor Capacitor
Capacitance
Voltage rating (nominal)
8 Mfd ±5%
450 V