Amana AAC101SRA Service Скачать руководство пользователя страница 1

Amana Technical Information

Room Air Conditioner

December 2002

16022064

(Replaces RT4110056 Rev. 0)

1

AAC101SRA

PAAC101SRA0

• 

Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this air conditioner.

• 

Refer to Service Manual 16022061 for installation, operation, disassembly, testing, and troubleshooting
information.

• 

Refer to Parts Reference material for part number information.

CAUTION

!

All safety information must be followed as provided in Service Manual 16022061.

!

WARNING

To avoid risk of electrical shock that can cause death or severe injury, disconnect unit from power and discharge
capacitor through a 10,000-ohm resistor before servicing, unless tests require power. Wires removed during
disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

Model

AAC101SRA

Electrical requirements

115 VAC 60Hz

Refrigerant/amount

R22/30 ounces

Compressor

Voltage low/high (nominal)
BTUH

98/132 VAC (115 VAC)
10,735 BTUH

Watts

1000 watts

Current

Lock rotor
Full load

54 amps
8.8 amps

Overload protector

External

Fan motor

Electrical requirements
RPM

Low speed
Med speed

High speed

Watts at high speed
Current at high speed

115 VAC 60Hz

730 RPM
830 RPM

1000 RPM

97 watts

2.1 amps

Compressor Capacitor

Capacitance
Voltage rating (nominal)

45 Mfd ±10%
250 V

Fan Motor Capacitor

Capacitance
Voltage rating (nominal)

8 Mfd ±5%
450 V

https://appliancetechmanuals.com