Amaircare 6000V Home Скачать руководство пользователя страница 4

FILTER REPLACEMENT INSTRUCTIONS

The 

AMERICAIR HEPA Air Filtration System

is designed to run continuously. To ensure

optimal performance, please carefully follow the Product Information and Owner’s
Manual Instructions.

FILTER REPLACEMENT INSTRUCTIONS:

1.

Read these instructions completely.

2.

Unplug your unit from the power supply outlet.

3.

Remove the safety screw from the top of the unit (located at the rear)

4.

Lift the front door of the unit up and pull it out to remove it from the unit. This will

allow access to the filter compartment.

5.

Unfasten the restraining strap(s) holding the filter(s) in place

6.

Remove the 

HEPA

cartridge(s) from the unit by turning it counter clockwise and lift out.

NOTE: The foam pre-filter and the 

HEPA

filter will contain contaminants. Remove

them slowly from the unit in order to avoid dusting.

7.

To remove the first-stage filter simply lift the foam from the bottom, pull it off.

Wash if desired, or replace with new

8.

To replace the first  stage filter pull the foam filter over the 

HEPA

cartridge and

gently pull it down until it completely covers the 

HEPA

filter (white portion).

9.

To replace the 3rd stage V.O.C. filter, fold the ends of the old Inner Blanket in, and

remove it from the unit. Insert the new Inner Blanket inside the HEPA Cartridge with
the edges overlapping. Once it is in position gently spread the Inner Blanket against
the HEPA filter until the two ends of the blanket meet.

10.

Replace the 

HEPA

cartridge, complete with the new pre-filter and inner blanket

(if changed) into the unit. Turn HEPA filter clockwise until it locks into position.

11.

Secure the Filters by tightly re-fastening the restraining straps over the top of the

Filter Assembly.

9.

After the filter(s) has been replaced, replace the top door, and replace the safety screw.

10.

Plug in the unit and turn it on.

OPERATING INSTRUCTIONS

With proper care and maintenance, you will enjoy many years of service and dra-
matically improve the quality of your indoor air. The 

AMAIRCARE

®

HEPA Air Filtration

System

is deigned to operate continuously.

INSTRUCTIONS

1. Plug the unit into a grounded outlet 120 Volt, 60 Hz (or 230 Volt, 50/60 Hz
Depending on the area in which the unit was sold).

2. Turn the unit on by flicking the power switch to the ‘on’ position

3. To turn the unit off, flick the power switch to the ‘off’ position

CAUTION!

1. Make sure that the line cord is not in the path of people walking or where any-
thing can be rolled over it.

2. Locate the unit such that there is no possibility of moisture dripping on it.
Moisture could leak into the unit and damage the filter or electrical components.

3. The Air Filtration System discharges clean air through the outflow screens on the
side (7500 Cart) or the front (6000V Cart) of the unit.

NOTE:  You may notice a slight “new” smell from the Air Filtration System when you
first turn it on. This is normal and harmless and it will dissipate within a few days.

HEPA Filter Replacement

As the HEPA filter captures particulates, it will darken over time.

Replace the HEPA filter when it darkens to example D.

A. New

B. Used

C. Used

D. Replace