Vipros 357 Queen with Fanuc 18PC User Pre-installation Guide
©Amada America, Inc.
Print Date 01/24/2001 Revision 4.0
This document available on the World Wide Web at http://www.amada.com
Page 16 of 37
Plan View - Vipros 357 Queen
with V357hs conveyor and MP1225 loader
V357hs Con
v
e
y
o
r
66"
39"
E3
Fanuc 18P Control
Hydraulic Unit
72.0" to Load Position
74.41" to Edge of Table
148.82" Machine Width
Access Required
this area for
scrap removal
55"
26
"
28"
59"
14"
30"
37"
57"
SBC 5.5 Chiller
P1
E2
E1
59.37" Maxim
um
10"
Machine
Center
line
VIPROS 357 QUEEN
Optional Material
Supports Required
Optional Material
Supports Required
50" W
o
rking
Range
100" Maxim
um
T
ra
v
el Area 50" Mater
ial
183.8" Machine Length
288.0" Maximum Material Travel Area 144" Material
389" Recommended Saf
ety / Maintenance Area 40" from all components
441" Recommended Safety / Maintenance Area 40" from all components
Electrical Requirements
Vipros 357 Queen
Vipros 357 Queen
Compressed Air Requirements
230 / 460 / 3 / 60 ±10% 30 kVA
SBC EX5.5 Chiller
230 or 460 / 3 / 60 ±10% 15 kVA
80 psi @ 8.8 ft³/min.
76 amps @ 230 / 3 / 60 VAC
38 amps @ 460 / 3 / 60 VAC
37 amps @ 230 / 3 / 60 VAC
19 amps @ 460 / 3 / 60 VAC
V357hs Conveyor
208 - 230 / 460 / 3 / 60 ±10% .8 kVA
2.1 amps @ 208 / 3 / 60 VAC
2.0 amps @ 230 / 3 / 60 VAC
1.0 amps @ 460 / 3 / 60 VAC
MP1225 Loader
MP1225 Loader
75 psi @ 31.8 ft³/min.
29 amps @ 200 / 3 / 60 VAC
200 / 3 / 60 ±10%, 10 Kva
To operate at 230 / 460 VAC a step up
transformer with the following service is
required
26 amps @ 230 / 3 / 60 VAC
13 amps @ 460 / 3 / 60 VAC
E1
E2
E3
E4
P1
P2
Scale
12"
12"
12"
MP1225
Xformer
MP1225 Loader
Forklift Access
Required This Area
For Material / Parts
Loading / Unloading
65.95"
188.06" MP1225 Length
75.41" to Edge of MP1225
217.15"
141.74" MP1225 Loader Width
P2
E4