Chapter
1
11
ML-9011A
1.3 Guidelines for Normal Use
•
If a computer is connected, never disconnect the LAN cable before turning off the MAIN POWER
switch.
•
For more consistent marking, allow the unit to warm up for about 10 to 30 minutes after turning
on the LD. The warmup time varies depending on the temperature and workpiece material.
•
In the LD starting state, you will see green light even when the laser is not emitted. Since it is
classified Class 1 or lower, it does not have a safety problem, but do not directly look it in.
•
When a supervisor or operator enters the area where the laser is used, safety measures not to
exceed the MPE* level must be provided.
* MPE: The maximum level of permissible exposure of the eyes or skin to laser beams.
Abbreviation of Maximum Permissible Exposure.
•
Since the surge absorber is built in, do not perform the insulation resistance test and the
withstand voltage test. If the surge absorber fails, the marker may become unusable.
For other information on managing laser equipment or the MPE level, refer to the
following standards.
・
JIS C 6802 "Safety of laser products"
・
Ministry of Health, Labour and Welfare Notification No. 0325002 "Prevention
measures against laser injuries" (in Japanese)