MD Series
7. Basic Operation
7-1
→
In most cases, AUTO should be used.
→
Set the nearest value above the welding current.
→
Select 2-step for welding.
→
Combination control of constant-current and constant-voltage.
→
Set 10 ms because of the sequencer (PLC) connection.
→
Set for operation only during input of the start signal.
→
Select the schedule with a parity from the sequencer.
→
Set the end signal output to 10 ms.
→
In most cases, it should be used as it is.
7.
Basic Operation
The operation method for
MD-A8000B
is given here as an example.
The settings to be made are as follows:
Schedule No.:
#15
Welding sequence: 2-step
Precheck function: ON
Welding method:
COMB.
Monitor values:
average current and average voltage
Change these settings to suit your purpose of use.
①
Refer to
5. Connection
, and connect peripheral equipment correctly to
MD-A8000B
.
②
Turn the POWER switch on and press the MENU key.
Check that the display screen and lamps are turned on normally
and the fan motor is operated.
③
Select STATUS by the cursor keys (
) and
press the ENTER key.
④
Set functions on the STATUS screen.
Move the cursor to the desired item and select
the function by the + and - keys.
Press the ENTER key, and the selected
function is valid.
⑤
Move the cursor to NEXT and press the ENTER key. The second screen appears.