6. Trouble Shooting:
Problem
Possible Cause
Remedy
The mixer
does not start
• Not plugged in
• The main switch is off
• Fuse overload at the power board
• The mixer overload has been activated
• Stop button still locked down
• Safety guard open
• Bowl and handle not raised
• Start button not depressed
• Plug in and switch on
• Turn on
• Contact supervisor
• Resets automatically(10
mins)
• Release by rotating and
pulling
• Close guard
• Pull handle and bowl up
• Press start button
The mixer
starts then
stops
• The mixers overload has been activated
• Fuse overload at the power board
• Resets automatically
(10mins). If overload occurs
repeatedly contact supervisor
or technical department.
The mixer
labours under
load
• Mix too stiff / tight
• Mechanical malfunction
• Loose belts or drive belts
• Review and adjust recipes
• Advise supervisor technical
department.
Electric motor
functions but
planetary
does not turn
• Electrical / Mechanical malfunction
• Switch off power at main
switch. Isolate moulder by
removing wall plug. Attach
danger tag to machine. Contact
technical department.
The mixer
does not stop
• Electrical / Mechanical malfunction
• Switch off power at main
switch. Isolate mixer by
removing wall plug. Attach
danger tag to machine. Contact
technical department.y