A
1035 22nd Avenue, Unit 1
n
Oakland, CA 94606
P
510.489.2530
E
[email protected]
W
alwusa.com
ILLUMINATE THE SOUL
INSTALLATION INSTRUCTIONS
LIGHTPLANE 9
LP9 | Suspended | LED
Страница 1: ...A 1035 22nd Avenue Unit 1 n Oakland CA 94606 P 510 489 2530 E TalkToUs alwusa com W alwusa com ILLUMINATE THE SOUL INSTALLATION INSTRUCTIONS LIGHTPLANE 9 LP9 Suspended LED...
Страница 2: ...uous row mounting 1 Lisez toutes les instructions 2 Installez conform ment la r glementation du code lectrique national et local 3 Ce produit est destin tre install et entretenu par un lectricien agr...
Страница 3: ...6 IG090320 A 0 Table of Contents Troubleshooting 9 Wiring Diagrams 10 Installation 5 Prepare Ceiling 5 Standard Suspension 5 Connecting Multiple Sections 7 Luminaire Overview 4 Diagrams 4 Components 4...
Страница 4: ...0 F 20 50 C Environment Dry and damp locations Quick Specs STANDARD SUSPENSION COMPONENTS Suspension Bullet Canopy Assembly Suspension Cable Ceiling Fitting J Box 4x4 Ceiling Fitting Suspension Bullet...
Страница 5: ...Fitting Framing C See final record drawings for mounting locations Install framing or strut channels with consideration for alignment of wiring and suspension mounting locations 1 See Final Record Dr...
Страница 6: ...f cable for adjustments 5 Cut Suspension Cables to Desired Length 8 Adjust Suspension Cable Length Adjust fixture until it is level and at desired height Depress top of Cable Gripper to lower fixture...
Страница 7: ...pinch wire connections 10B Combo Canopy Installation DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while installing canopy Mount Canopy Bracket to J Box using appropriate mounting hardware then secu...
Страница 8: ...ch metal cover CAUTION Do not pinch wires while reattaching 19 Re install Cover Tighten joiner screws as shown using a 5 64 Hex Key Ensure each section is properly aligned and that there are no gaps b...
Страница 9: ...omer support Only a certified electrician can service and troubleshoot product field issues Always turn main power off before servicing fixture Fixture section s do not illuminate Possible loose low v...
Страница 10: ...e Red Line Voltage Hot Line Voltage Neutral Ground 0 10VDC Dim 0 10VDC Dim L N AC 50 60Hz DIM DIM 0 10V Dimming Black White Green Clear Black DMX in shield DMX in Line Voltage Hot Line Voltage Neutral...
Страница 11: ...Diagrams Cont Black White Green Blue Red Line Voltage Hot Line Voltage Neutral Ground Dali Dali L N AC 50 60Hz DALI DALI DALI Canopy Power Feed Black White Green Red Blue Line Voltage Hot Line Voltag...