![Alvarion BreezeACCESS 900 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/alvarion/breezeaccess-900/breezeaccess-900_installation-manual_2915131025.webp)
Preliminary Configuration
3-3
Configuring Basic Parameters
The
Basic Configuration
menu of the Monitor program includes all the
parameters necessary for the initial operation of BreezeACCESS SU-M-900.
YOU MUST PERFORM A SITE SURVEY AND SPECTRUM SWEEP PRIOR TO
CONFIGURING THE AU’S IN ORDER TO DETERMINE THE AVAIABLE
CLEAR CHANNELS.
The following list includes the basic parameters and their default values
(applies to Version 4.3.9):
Parameter
Default Value
Comment
IP Address
10.0.0.1
Subnet Mask
255. 0.0.0
Default Gateway Address
0.0.0.0
Transmit Antenna
Antenna 2 in
software. DO NOT
CHANGE
USE ANT 1 PHYSICAL
PORT, ANT 2 NOT
CONNECTED.
ESSID
ESSID1
Must be the same as the
ESSID the Base Station AU.
Hopping channels
None
Configure according to site
survey results
Best AU Support
enable
Set scanning time
Best AU scanning time
Set to 7
Makes roam decision faster
Scan Entire band
Disable
Set only to channels used
in all AUs
Max number of Bad Synch
Set to 115
Max number of Assoc/Auth
TimeOut
Set to 100
Improves roaming
performance in edge areas
Number of Dwells to
retransmit
Set to 1
Max TX Data Rate
Set to 2 Mbps
Improves throughput by
limiting multi-rate
algorithm
Operator ESSID
Disable
Enable if using operator
ESSID on all AU cells.
Once the basic parameters are configured, the unit must be reset to
activate the new configuration.