INSTALLATION AND OPERATION MANUAL | CUL11 CONTROL UNIT
5
5
TEChNICAL SPECIFICATIONS
3.
TEChNICAL SPECIFICATIONS
Parameter name
Parameter name
Value
Value
Supply voltage
3 ~ 400 V ± 10 %
Supply frequency, Hz
50
Electric motor power, kW
≤ 1.5
Power demand in standby, W
≤ 5
Valve rated supply voltage
24 V DC
Valve rated power, W
18
Auxiliary equipment power supply
(optical door position sensor)
24 V DC / max. 100 mA
Light lamp power supply
230 V / max. 100 W
Section of wires to be connected to connectors, mm
2
max. 2.5
IP degree of protection
IP54 (professional installation)
Operating temperature range, º С
– 25 … + 40
Overall dimensions, mm
190 × 280 × 145
4.
ELECTRIC MODULE
The electric module to which other devices are connected (
fig.
2) is located inside the control unit.
List of module elements
Element
Element
Description
Description
FU1
T10А500V fuses
CAUTION!
Use quartz-sand-filled fuses
FU2
FU3
FU4
T2А500V fuse
CAUTION!
Use quartz-sand-filled fuse
FU5
T3.15А250V fuses
FU6
FU7
hL1
LED
indicating the operation of control buttons
2
and
3
(
fig.
1). Lights up when
the control button is pressed
hL2
LED
indicating the electric motor overcurrent in hydraulic unit. Lights up when
the overcurrent protection is triggered
hL3
LED
indicating the connection of hydraulic unit valves. Lights up when valves are not
connected to
VAL1
and
VAL2
outputs (or to one of the outputs)
hL4
LED
indicating the state of door position sensor. Lights up when the sensor is activated
hL5
LED
indicating the operation of valve connected to
VAL1
output. Lights up when the
valve is not connected to
VAL1
output or voltage is supplied to the valve