OPERATING MANUAL. INDUSTRIAL SECTIONAL DOORS
2
PRODUCT DESCRIPTION
1.
PRODUCT DESCRIPTION
1.1
PRODUCT FUNCTION AND SERVICE CONDITIONS
This Operating manual applies to ProPlus, ProTrend, AluPro, AluTherm, AluTrend sectional doors
designed to be installed in industrial, public and office buildings in order to prevent the unau-
thorised access into the premises and to ensure good thermal and sound insulation.
The doors are not designed to be installed in explosive and fire-hazardous buildings, or to act
as fire barriers closing off openings.
The doors are designed for operation in following temperature conditions:
•
upper operating tempe 40 º С;
•
lower operating temperature − 45 º С;
•
upper limit operating tempe 45 º С;
•
lower limit operating temperature − 50 º С.
Notes.
1. The operating temperatures are temperatures needed to ensure the maintenance
of required properties and economically expedient service life of the product.
2. The limit operating temperatures are acceptable temperatures (for limited exposure
and not for more than 6 hours, and for lower temperatures less than 12 hours) during
door operation. If the doors are used in limit operating temperatures, they must:
•
keep functionality, but will not correspond obligatorily to nominal characteristics;
•
renew all nominal characteristics after the temperatures turn to normal.
When operating the doors under conditions, leading to significant temperature difference of
outer and inner surfaces of the door leaf (mounting of dark-colored doors, which have low
reflectivity, on the sunny side of buildings and constructions; door operating in the heated
premises at low outdoor temperatures etc.) the bending of sandwich panels, caused by the
thermal expansion / contraction of the steel sheets, is possible. That can lead to door damage
when opening and closing. In case of bending, exceeding the value of 1 / 150 of opening width,
due to the conditions described above, the operation of the door is to be stopped until the
temperature difference between the outer and inner surfaces of the leaf is reduced.
The doors are designed for operating under the following relative air humidity conditions:
•
up to 90 % indoors;
•
up to 100 % outdoors.
The doors are manufactured with manual or automatic control systems.
The electric motors are designed to be plugged into electric networks with a frequency of 50 Hz
and nominal voltage of 230 V or 400 V. The usage of electric motors is possible while the ambient
temperatures are from − 20 º С up to + 50 º С.
The doors are installed behind the opening inside the premises on a substrate such as concrete,
brickwork, metalwork or a combination of these materials.