1
Max. 30cm
MOUNT TRUSS PROFILE
2
h
CONNECT THE TRUSS PROFILES
Necessary when the width of the module field is greater than the length of
the truss profile.
Push the profile connector halfway into the first truss profile, then connect
the second truss profile to the profile connector.
MOUNTING THE TRUSS PROFILE – SINGLE DIRECTION
Profile connector
Fasteners
Fasteners
Fasteners
Fasteners
Fasteners
Fasteners
Profile connector
Please note:
-
Every truss profile must be attached in at least two places!
-
Truss profile end contact surfaces must not be situated at points of
attachment.
-
Truss profile length:
max. 12m
!
-
Ensure an expansion joint of at least
5cm
is included at a maximum of
every
12m
!
-
Extensions of the truss profiles beyond the final point of attachment
must not exceed
30cm
!
-
Measure the correct positions for the profile connectors according
to the
Solar.Pro.Tool project report
and optionally
screw down
the pro
file connector.
Final fastener
Mount the truss profile onto the roof hooks, parallel to the ridge of the roof,
with the correct side up, and tighten to a torque of
15 Nm
.
Top
Bottom