The RE609 Glassbreak

 

is a security sensor that detects the sound of 

breaking glass and sends alarm signals to the security panel.  

Features

•  360 degree omni-directional coverage

•  Optional external contact 

•  Low battery indication

•  5-year warranty

Enroll

 

by placing the panel into wireless enrollment mode and sending 

an enrollment signal. Alternatively, the sensor can be enrolled by 

scanning its bar code using the Installer App or by entering 

its 8-character serial number on the interactive service provider’s web 

portal.                     

                    

Install

 

by mounting the sensor at least 3 feet (~1 m), but no more than 

25 feet (~7.5m), from a window using the mounting screw locations 

or VHB tape.  Ensure that the sensor has visual line-of-sight to all 

windows being protected. 

Glassbreak Testers

 

should be used to verify operation after 

enrollment and installation (use any glassbreak tester).

•  Putting Sensor in Test Mode:

1. Put tester on tempered setting.
2. Hold tester next to the microphone and activate tester.
3. The red LED will light for 4 seconds.
4. Sensor sends alarm to control panel.

•  Red LED will blink one time per second for one minute (Test Mode).

•  Every time the sensor hears the tester in Test Mode, the red LED  

 

will light for four seconds and sensor sends alarm.

•  In Test Mode:

1. Test sensor distance – holding tester near surface of the 

window protected, activate tester with speaker pointed 

towards sensor.

2. If the red LED does not light for 4 seconds, relocate sensor 

and retest.

3. When location is verified and a good test is confirmed, the 

red LED will stop blinking 1 minute after last tester sound 
it hears.

NOTE: The pattern recognition technology of this sensor 

ignores most false alarm sounds, including glassbreak 
testers (except in test mode).

Optional External Contact

 

may be enrolled as an additional zone.  

In order to use the external contact, it must be enabled using the 

Installer App or the interactive service provider’s web 

portal.

Use the panel installation guide to verify proper system setup.

Enroll Button

External Contact 

Terminal Block

LED

RE609 Glassbreak  

 Encrypted

IN

STALL

G

U I D E

I

Sending an Enrollment Signal

•  Remove the battery tab and press the 

enrollment button

External Contact 

•  Connect the external contact to terminal B 

and the middle terminal 

•  Use only a 

normally-closed 

contact

•  Do not use end-of-line resistors