Use the panel installation guide to verify proper system setup.
The Home Disaster
is an integrated environmental sensor
that detects flood and extreme temperature conditions.
Features
•
Titanium probes for unmatched corrosion immunity
•
Detects flood, freeze, and heat conditions
•
Secure encrypted wireless transmissions
•
5-year warranty
Enroll
the flood sensor (first ID) by placing the panel into
wireless enrollment mode and then sending an enrollment
signal from the sensor.
Options for Sending an Enrollment Signal
•
Remove the battery tab and cover to trip tamper.
Freeze & heat inputs must be enabled as additional
zones to function. Activate only the zones needed in
order to extend battery life.
To activate and enroll a freeze input (second ID):
•
Remove magnet from reed switch
•
Hold down tamper and install battery
To activate and enroll a heat input (third ID):
•
Have magnet next to reed switch
•
Hold down tamper and install battery
Install
by placing the remote flood probe in the location
requiring flood or leak detection. If desired, the flood
probe can be screwed to the floor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the flood probe wires to the
sensor’s terminal blocks.
Detects
water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
•
Heat alarms when over 100°F (38°C)
•
Heat restores when under 97°F (36°C)
•
Freeze alarms when under 45°F (7°C)
•
Freeze restores when over 48°F (9°C)
RE119 Home Disaster
™