Use the panel installation guide to verify proper system setup.

The Home Disaster 

is an integrated environmental sensor 

that detects flood and extreme temperature conditions.  

Features

• 

Titanium probes for unmatched corrosion immunity 

• 

Detects flood, freeze, and heat conditions

• 

Secure encrypted wireless transmissions

• 

5-year warranty

Enroll

 the flood sensor (first ID) by placing the panel into 

wireless enrollment mode and then sending an enrollment 

signal from the sensor.

Options for Sending an Enrollment Signal

• 

Remove the battery tab and cover to trip tamper.

Freeze & heat inputs must be enabled as additional 

zones to function. Activate only the zones needed in 

order to extend battery life. 

 

To activate and enroll a freeze input (second ID):

• 

Remove magnet from reed switch

• 

Hold down tamper and install battery

 

To activate and enroll a heat input (third ID):

• 

Have magnet next to reed switch

• 

Hold down tamper and install battery

Install 

by placing the remote flood probe in the location 

requiring flood or leak detection.  If desired, the flood 

probe can be screwed to the floor or baseboard.  Next, 

mount the sensor to the wall using the mounting screw 

locations.  Finally, connect the flood probe wires to the 

sensor’s terminal blocks.  

Detects

 

water pooled under the sensor and reports extreme 

temperature conditions.

Default Temperature Trip Points

• 

Heat alarms when over 100°F (38°C)

• 

Heat restores when under 97°F (36°C)

• 

Freeze alarms when under 45°F (7°C)

• 

Freeze restores when over 48°F (9°C)

RE119 Home Disaster

Interlogix

®

 Compatible

IN

ST

A

LL

G

U

I

D E

I

Mounting

Screw

Holes

Wire

Entry

Hole