WayPoint562
- 3 -
Technical Specifications:
Parameter
Description
Input power
requirements
115VAC, 60Hz, 2.5A or 230VAC, 50/60Hz, 1.3A.
Environmental
Conditions
Operating Ambient Temperature:
60W: -40ºC to 75ºC (-40ºF to 167ºF);
75W: -40ºC to 70ºC (-40ºF to 158ºF);
100W: -40ºC to 55ºC (-40ºF to 131ºF);
120W: -40ºC to 45ºC (-40ºF to 113ºF).
Relative Humidity: 85%, +/- 5%.
Storage Temperature: -40ºC to 85ºC (-40ºF to 185ºF).
Operating Altitude: -304.8 to 2,000m.
Weights (approx.)
Product weigtht: 8.5 lb. (3.9 kg) | Shipping weigtht: 9.7 lb. (4.4 kg).
Terminal Identification:
Terminal Legend
Function/Description
L, G, N
Connect 115VAC/230VAC to these terminals: L to Hot, N to Neutral.
– DC +
56VDC @ 2.2A continuous supply current.
– BAT +
Stand-by battery connections. Maximum charge rate 0.7A.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user
to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may
be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the
appliance.
CAUTION: To reduce the risk of electric shock do not open
enclosure. There are no user serviceable parts inside.
Refer servicing to qualified service personnel.
Bottom of Enclosure