- 2 -
WayPoint10A Series
Overview:
Altronix WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or
eight (8) outputs for powering CCTV cameras, heaters, and other video accessories.
WayPoint10A Series AC Reference Chart:
Altronix
Model Number
Output Voltage
Total
Output
Current
(Power)
Number
and Type
of Outputs
Fuse
Output
Ratings PTC Output Ratings
Class 2 Rated
power-limited
outputs
Input Current
Draw
Product
Weight
115VAC
60Hz
230VAC
50Hz
WayPoint10AU
24VAC
4A
1
5A/
32V*
–
–
1.0A
0.5A
4.68kg
28VAC
3.5A
24VAC and 28VAC
3.5A
1 of each
WayPoint10ADU
24VAC
4A
1
–
9A
P
4.68kg
28VAC
3.5A
24VAC and 28VAC
3.5A
1 of each
WayPoint10A4U
24VAC
4A
4 Fused
5A/
32V*
–
–
4.8kg
28VAC
3.5A
WayPoint10A4DU
24VAC
4A
4 PTCs
–
2.5A
P
4.8kg
28VAC
3.5A
WayPoint10A8U
24VAC
4A
8 Fused
5A/
32V*
–
–
4.95kg
28VAC
3.5A
WayPoint10A8DU
24VAC
4A
8 PTCs
–
2.5A
P
4.95kg
28VAC
3.5A
*Lower rated fuses can be used.
Specifications:
Installation Instructions:
Unit shall be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 4).
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.
3. Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the
enclosure flange. Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).
4. Mount back plane to enclosure with hardware.
5. Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6. To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7. Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8. Connect unswitched AC power (115VAC/230VAC, 50/60 Hz) to terminals marked [L, N]
(Figs. 2-4, pgs. 4-6). Green branch wire connects to earth (safety) ground lug .
Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).
9. Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).
Agency Listings:
• UL/cUL Listed:
UL 60950-1 Information Technology Equipment.
UL 60950-22 Equipment to be Installed Outdoors.
• CE European Conformity.
Input:
• Input: 115VAC, 60Hz,1A or 230VAC, 50Hz, 0.5A.
Output:
• Output options:
a. 24VAC or 28VAC.
b. Both 24VAC and 28VAC
(WayPoint10AU/ADU
only).
• Fuse ratings:
WayPoint10A Series incorporate 5A/32V fuses.
Visual Indicators:
• Individual power output LED indicators.
• Illuminated master power switch.
Features:
• Surge suppression.
• Spare fuses included.
Accessories:
• Optional PMK1 Pole Mount Kit simplifies
installation of outdoor units.
Enclosure:
• NEMA 4/4X, IP66-11 Rated enclosure for
outdoor use.
• Enclosure Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.1 mm x 287.3 mm x 142 mm).
COM 24V 28V
COM 24V 28V
28V 24V COM
CAUTION
HIGH VOLTAGE
PD2WP
Input Voltage
Power Input
115V
115
230
L
G
N
5
5
5
5
Ground
Lug
ALTRONIX CORP.
www.altronix.com
BROOKLYN,NY 11220
PD2WP
COM 24V 28V
COM 24V 28V
28V 24V COM
Input Voltage
Power Input
115V
115
230
L
G
N
ALTRONIX CORP.
www.altronix.com
BROOKLYN, NY 11220
Circuit board incorporated
in WayPoint10ADU (PTCs)