background image

 

- 2 - 

WayPoint10A Series

Overview:

Altronix WayPoint Outdoor Power Supplies provide 24VAC and/or 28VAC distributed via two (2), four (4) or 
eight (8) outputs for powering CCTV cameras, heaters, and other video accessories.

WayPoint10A Series AC Reference Chart:

Altronix 
Model Number

Output Voltage

Total

Output 

Current

(Power)

Number

and Type

of Outputs

Fuse

Output

Ratings PTC Output  Ratings

Class 2 Rated

power-limited 

outputs

Input Current 

Draw

Product

Weight

115VAC

60Hz

230VAC

50Hz

WayPoint10AU

24VAC

4A

1

5A/

32V*

1.0A

0.5A

4.68kg

28VAC

3.5A

24VAC and 28VAC

3.5A

1 of each

WayPoint10ADU

24VAC

4A

1

9A

P

4.68kg

28VAC

3.5A

24VAC and 28VAC

3.5A

1 of each

WayPoint10A4U

24VAC

4A

4 Fused

5A/

32V*

4.8kg

28VAC

3.5A

WayPoint10A4DU

24VAC

4A

4 PTCs

2.5A

P

4.8kg

28VAC

3.5A

WayPoint10A8U

24VAC

4A

8 Fused

5A/

32V*

4.95kg

28VAC

3.5A

WayPoint10A8DU

24VAC

4A

8 PTCs

2.5A

P

4.95kg

28VAC

3.5A

*Lower rated fuses can be used.

Specifications:

Installation Instructions:

Unit shall be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1.  Remove backplane from enclosure prior to mounting (do not discard hardware).
2.  Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 1, pg. 4).
 

Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. 

 

UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.

3.  Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the 
 

enclosure flange. Secure enclosure with appropriate fasteners (Fig. 5, pg. 7 and Fig. 11, pg. 8).

4.  Mount back plane to enclosure with hardware.
5.  Set the input voltage selector switch for 115VAC or 230VAC operation (Figs. 2-4, pgs. 4-6)
6.  To facilitate wire entry utilize weather-tight NEMA 4 rated connectors, bushings, and cable.
7.  Set illuminated master power disconnect circuit breaker to the [OFF] position (Figs. 2-4, pgs. 4-6).
8.  Connect unswitched AC power (115VAC/230VAC, 50/60 Hz) to terminals marked [L, N] 
 

(Figs. 2-4, pgs. 4-6). Green branch wire connects to earth (safety) ground lug      .

 

Wire gauge range of connectors is 14 AWG to 11 AWG (1.6 mm to 2.5 mm diameter).

9.  Set illuminated master power disconnect circuit breaker to the [RESET/ON] position (Figs. 2-4, pgs. 4-6).

Agency Listings:

•  UL/cUL Listed: 
 

UL 60950-1  Information Technology Equipment.

 

UL 60950-22 Equipment to be Installed Outdoors. 

•  CE European Conformity.

Input:

•  Input: 115VAC, 60Hz,1A or 230VAC, 50Hz, 0.5A.

Output:

•  Output options:
  a.   24VAC or 28VAC.
  b.  Both 24VAC and 28VAC 
  (WayPoint10AU/ADU 

only).

•  Fuse ratings:
    WayPoint10A Series incorporate 5A/32V fuses.

Visual Indicators:

•  Individual power output LED indicators.
•  Illuminated master power switch.

Features:

•  Surge suppression.
•  Spare fuses included.

Accessories:

•  Optional PMK1 Pole Mount Kit simplifies 
  installation of outdoor units.

Enclosure:

•  NEMA 4/4X, IP66-11 Rated enclosure for 
  outdoor use.
•  Enclosure Dimensions (H x W x D approx.):
  13.31” x 11.31” x 5.59”  

 

  (338.1 mm x 287.3 mm x 142 mm).

COM    24V      28V

COM    24V      28V

28V     24V    COM

CAUTION

HIGH VOLTAGE

PD2WP

Input Voltage

Power Input

115V 

115

230

L

G

N

5

5

5

5

Ground

Lug

ALTRONIX CORP.

www.altronix.com

BROOKLYN,NY 11220

PD2WP

COM    24V      28V

COM    24V      28V

28V     24V     COM

Input Voltage

Power Input

115V 

115

230

L

G

N

ALTRONIX CORP.

www.altronix.com

BROOKLYN, NY 11220

Circuit board incorporated

in WayPoint10ADU (PTCs)

Содержание WayPoint10A Series

Страница 1: ...C 4A or 28VAC 3 5A Four 4 fuse protected outputs WayPoint10A8U 24VAC 4A or 28VAC 3 5A Eight 8 fuse protected outputs WayPoint10ADU 24VAC 4A and or 28VAC 3 5A Two 2 Class 2 Rated PTC protected power li...

Страница 2: ...bottom holes of the enclosure flange Secure enclosure with appropriate fasteners Fig 5 pg 7 and Fig 11 pg 8 4 Mount back plane to enclosure with hardware 5 Set the input voltage selector switch for 11...

Страница 3: ...icted service area use lock or other fastened means on door latches This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local cod...

Страница 4: ...8V 24V COM CAUTION HIGH VOLTAGE PD2WP Input Voltage Power Input 115V 115 230 L G N 5 5 5 5 Ground Lug ALTRONIX CORP www altronix com BROOKLYN NY 11220 PD2WP COM 24V 28V COM 24V 28V 28V 24V COM Input V...

Страница 5: ...3 COM 4 COM Input Voltage Power Input ALTRONIX CORP www altronix com BROOKLYN NY 11220 115V 115 230 L G N S P N 5 5 5 5 1 COM 2 COM PD4WP 3 COM 4 COM Input Voltage Power Input 115V 115 230 L G N S P...

Страница 6: ...Voltage Power Input 115V 115 230 L G N S P N 1 2 3 4 5 6 7 8 5 5 5 5 5 5 5 5 1 2 3 4 5 6 7 8 Common PD8WP Input Voltage Power Input 115V 115 230 L G N S P N 1 2 3 4 5 6 7 8 Used on WayPoint10A8DU Grou...

Страница 7: ...strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 7 pg 8 and Fig 9 pg 7 3 Attach the bottom bracket to the enclosure by i...

Страница 8: ...MEMBER Enclosure Dimensions H x W x D approx 13 31 x 11 31 x 5 59 338 1mm x 287 3mm x 142mm 1 61 40 9mm 3 96 100 6mm 5 59 142mm 10 32 X 0 375 9 6mm BRASS INSERT X4 STAINLESS STEEL PIANO HINGE 11 31 28...

Отзывы: