WayPoint DC Series Installation Guide 

- 3 -

11.  Connect devices to be powered to the terminals marked [– DC +] 

(Fig. 2b, pg. 4, Fig. 3b, pg. 5)

.

12.  Connect optional stand-by battery to the terminals marked [– BAT +]. Battery leads included. 

 

Enclosure accommodates up to two (2) 12VDC/7AH batteries. If larger batteries are required, they need to 

 

be mounted in a separate NEMA rated enclosure adjacent to the power supply 

(Fig. 2b, pg. 4, Fig. 3b, pg. 5)

.

 

Note:

 When batteries are not used, a loss of AC will result in a loss of output voltage.

13.  Set power switch, if applicable, to the ON position 

(Fig. 2c, pg. 4).

14.  Upon completion of the wiring secure enclosure door with latches and optional lock.

CAUTION: Equipment to be installed / serviced by authorized / trained personnel only. 

Shut branch circuit power before installing / servicing equipment.

WARNING: When installing in a non-restricted service area, use lock or other fastened means on door 

latches. This installation should be made by qualified service personnel and should conform to the 

National Electrical Code and all local codes.

LED Diagnostics:

Red (DC)

Green (AC)

Power Supply Status

ON

ON

Normal operating condition.

ON

OFF

Loss of AC. Stand-by battery supplying power.

OFF

ON

No DC output. Short circuit or thermal overload condition.

OFF

OFF

No DC output. Loss of AC. Discharged or no battery present.

Terminal Identification:

Terminal Legend

Function/Description

– DC +

WayPoint3: 

12VDC or 24VDC @ 2.5A supply current.

WayPoint5: 

12VDC or 24VDC @ 3.5A supply current.

WayPoint7: 

12VDC or 24VDC @ 6A supply current.

WayPoint7: 

12VDC or 24VDC @ 6A supply current.

WayPoint1012V: 

12VDC @ 10A supply current.

– BAT +

Stand-by battery connections. Maximum charge rate 500mA (700mA for WayPoint1012V).

Bottom of Enclosure

Suggested

Locations

for Wiring Inlets

Fig. 1

Содержание WayPoint DC Series

Страница 1: ...C or 24VDC 230VAC input WayPoint1012V 10A 12VDC 230VAC input WayPoint DC Series DC Outdoor Power Supply Chargers Models Include Rev 080911DCPL More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide ...

Страница 2: ...2VDC 7AH batteries Installation Instructions Wiring methods should be in accordance with the National Electrical Code NFPA 70 NFPA 72 ANSI and with all local codes and authorities having jurisdiction 1 Remove backplane from the enclosure prior to mounting do not discard hardware 2 Mark and drill desired inlets on the enclosure to facilitate wiring Fig 1 pg 3 3 Mount unit in the desired location Fo...

Страница 3: ... installing servicing equipment WARNING When installing in a non restricted service area use lock or other fastened means on door latches This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes LED Diagnostics Red DC Green AC Power Supply Status ON ON Normal operating condition ON OFF Loss of AC Stand by battery supplyi...

Страница 4: ...C Series Installation Guide Fig 2 WayPoint3 WayPoint5 WayPoint7 and WayPoint7V L G N OFF ON OFF ON CAUTION HIGH VOLTAGE BAT DC AC DC BAT DC 5A 250V OFF 24V ON 12V ON OFF 24V ON 12V ON Ground Lug Fig 2a Fig 2c Fig 2b ...

Страница 5: ...WayPoint DC Series Installation Guide 5 Fig 3 WayPoint1012V CAUTION HIGH VOLTAGE L G N DC BAT FAIL NC C NO NC C NO BAT AC FAIL 15 5A 250V VR1 AC DELAY DC BAT Ground Lug Fig 3a Fig 3b ...

Страница 6: ...at may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor tant operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing t...

Страница 7: ...end of the strap through the locking mechanism on the strap then tighten the screw with flat head screwdriver or 5 16 hex socket driver Fig 6 pg 7 and Fig 8 pg 7 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 7 pg 7 4 Thread the second wormgear quick release strap through the slots...

Страница 8: ...H x W x D approximate 13 31 x 11 31 x 5 59 338 1mm x 287 3mm x 142mm 5 59 142mm PADLOCK LATCH ATTACHED WITH RIVETS Ø 0 375 9 5mm PADLOCK EYE Ø 0 32 8 1mm MOUNTING HOLE TYP 4 PLACES 8 00 203 2mm STAINLESS STEEL PIANO HINGE 10 75 273 1mm 10 00 254mm 8 25 209 6mm 10 25 260 4mm 12 00 304 8mm 13 50 342 9mm 10 32 X 0 25 6 4mm BRASS INSERT X2 1 61 40 9mm 3 96 100 6mm 12 75 323 9mm 11 31 287 3mm 13 31 338...

Отзывы: