Overview:

Altronix VertiLine Rack Mount Power Supplies provide sixteen (16) filtered and electronically regulated power outputs 
in a space saving 1U EIA 19”    rack mount chassis. The units are available with either 12VDC or 24VDC power outputs. 
Vertiline Rack Mount Power Supplies are also available with eight (8) outputs.

Specifica tions:

Sixteen (16) Output Rack Mount Configuration Reference Chart:

Altronix
Model Number

Output 

Voltage

Total Output

Current 

(Power)

Number of 

Outputs

PTC Output 

Protection

Current (max. 

per output)

115VAC 60Hz
Input Current

VertiLine33D

12VDC

8A

16

PTC

2.5A

1.5A

VertiLine33TD

12VDC

16A

16

PTC

2.5A

3A

VertiLine63D

24VDC

8A

16

PTC

2.5A

3A

VertilLine63TD

24VDC

16A

16

PTC

2.5A

6A

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This 

installation should be made by qualified service personnel and should conform to the National Electrical 

Code and all local codes.

Installation Instructions:

1.  Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 3-4, pg. 7).
 

Affix rubber pads to Vertiline for shelf installation (Fig. 5, pg. 7).

2.  Secure the unit into rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” 
 

from any video monitors). When installing the unit in a rack allow for one half U spacing above the unit

 

for ventilation.

3.  Insert and secure removable terminal blocks to unit (Fig. 1e, pg. 4).
4.  Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1d, pg. 4)
 

Insert the plug end of the line cord into a grounded AC receptacle.

5.  Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 1c, pg. 4).
6.  Measure output voltage before connecting cameras/devices. This helps avoiding potential damage.
7.  Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1c, pg. 4)
8.  Connect the power output of terminals marked [+ 1 ---  ] to the power input of device (Fig. 1b, pg. 4).
 

Repeat this step for each additional device (Outputs 2-16).

9.  Upon completion of wiring, set illuminated master power disconnect circuit breaker to the 
 

ON (RESET) position (Fig. 1c, pg. 4).

Agency Listing:

•  CE European Conformity.

Input:

•  115VAC 60 Hz.

Output:

•  Filtered and electronically regulated outputs.
VertiLine33D, VertiLine33TD:
•  Sixteen (16) PTC protected 12VDC power outputs.
VertiLine63D, VertiLine63TD:
•  Sixteen (16) PTC protected 24VDC power outputs.

Features:

•  Sixteen (16) power LED indicators.
•  Illuminated master power disconnect circuit breaker
  with manual reset.
•  IEC 320 - 3-wire grounded line cord (detachable).
•  Removable terminal blocks with locking screw flange.

Mechanical:

•  Units can be rack, wall or shelf mounted.
•  Modular 1U standard EIA 19” rack mount chassis.
•  Enclosure Dimensions (H x W x D approx.):
  1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).

Содержание VertiLine33D

Страница 1: ...e VertiLine33D 12VDC 8A Sixteen 16 PTC protected outputs VertiLine33TD 12VDC 16A Sixteen 16 PTC protected outputs VertiLine63D 24VDC 8A Sixteen 16 PTC protected outputs VertiLine63TD 24VDC 16A Sixteen 16 PTC protected outputs Rev 090810 More than just power TM ...

Страница 2: ...When installing the unit in a rack allow for one half U spacing above the unit for ventilation 3 Insert and secure removable terminal blocks to unit Fig 1e pg 4 4 Plug the grounded AC line cord included into the IEC 320 connector of the Vertiline unit Fig 1d pg 4 Insert the plug end of the line cord into a grounded AC receptacle 5 Set illuminated master power disconnect circuit breaker to the ON p...

Страница 3: ... breaker is OFF or tripped c One 1 or more power output PTCs are tripped due to a short circuit or overload condition To reset the PTC 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1c pg 4 2 Eliminate the trouble condition short circuit or overload 3 Allow 1 minute for PTC to cool off reset 4 Set illuminated master power disconnect circuit breaker to the ON posi...

Страница 4: ...Vertiline63TD rear 1a 1b 1c 1d 1a LED s 1 8 Power LED indicators 1b Power Outputs 12VDC or 24VDC 1c Illuminated master power disconnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1d IEC 320 Connector 115VAC 60Hz grounded line cord included 1e Removable Terminal Block 1e Removable Terminal Block ...

Страница 5: ...D VertiLine63TD 5 Fig 2 Typical Application Drawing 12VDC Vertiline33D Vertiline33TD or 24VDC Vertiline63D Vertiline63TD Power Outputs to Devices 12VDC Vertiline33D Vertiline33TD or 24VDC Vertiline63D Vertiline63TD Power Outputs to Devices ...

Страница 6: ...d Outputs not powered To reset circuit breaker set power switch to the ON RESET position The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is in...

Страница 7: ...d screws from both sides of rack chassis Fig 3a 2 Attach mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 3b 3 Install unit into desired EIA 19 rack position and secure with mounting screws not included Fig 3c Fig 5 Fig 4 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 5 2 Plac...

Страница 8: ...TD Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline33DSeries F14P Notes MEMBER ...

Отзывы: