background image

 

- 4 -  

Trove3 Mercury V Kits Installation Guide

T3MK77F16V and T3MK77F16DV: Configuration of Mercury Boards on TM3:

1.  Fasten snap on spacers onto metal pems configuration (A) (B) of backplane depending on the access controller 

(Fig. 3, pg. 4)

.

2.  Position access controller module over corresponding spacers and depress onto snap on spacers 

(Fig. 3a, pg. 4)

.

3.  Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models:

Mercury Access Controller

Pem Mounting

EP1502, MR52, MR16IN, MR16OUT

A

EP2500, MUX8

B

EP1501, MR51e

C

MR52

D

Fig. 3

D

B

B

A

A

A

A

A

A

A

A

C

Altronix eFlow104NBV

–   DC   

+

–   BAT   

+

L         G          N

Altronix eFlow104NBV

–   DC   

+

–   BAT   

+

L         G          N

RSB2

OUTPUT 1     OUTPUT 2         OUTPUT 3         OUTPUT 4          OUTPUT 5        OUTPUT 6         OUTPUT 7        OUTPUT 8

NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C NO COM NC C NO COM

 IN  GND IN GND IN GND IN GND

IN  GND IN GND IN  GND IN GND

1            2           3          4

5           6           7           8

 INPUT

TRIGGER

10A 250V

+INP-  T + RET-

NO  C   NC

FACP            INTERFACE

Power   Control

-      +      -      

+

MAIN

TRG

FACP

1     2     3     4

1     2     3     4

O N

O N

1     2     3     4

1     2     3     4

O N

O N

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

8

D1

INPUT

P        N

R1

LED

Altronix PD8UL(CB)

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

8

D1

INPUT

P        N

R1

LED

Altronix PD8UL(CB)

Altronix ACM8(CB)

OUTPUT 1     OUTPUT 2         OUTPUT 3         OUTPUT 4          OUTPUT 5        OUTPUT 6         OUTPUT 7        OUTPUT 8

NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C  NO COM NC C NO COM  NC  C NO COM NC C NO COM

 IN  GND IN GND IN GND IN GND

IN  GND IN GND IN  GND IN GND

1            2           3          4

5           6           7           8

 INPUT

TRIGGER

10A 250V

+INP-  T + RET-

NO  C   NC

FACP            INTERFAC

E

Power   Control

-      +      -      

+

MAIN

TRG

FACP

1     2     3     4

1     2     3     4

O N

O N

1     2     3     4

1     2     3     4

O N

O N

Altronix ACM8(CB)

Snap On

Spacer

Mercury Board

Backplane

Pem

Fig. 3a

Содержание Trove3M3V Kit Series

Страница 1: ...ply Charger One 1 eFlow102NBV Power Supply Charger Two 2 ACM8CB PTC Protected Access Power Controllers One 1 PD8ULCB PTC Protected Power Distribution Module One 1 Rocker Switch Bracket with Two 2 Rock...

Страница 2: ...nt access Enclosure Dimensions H x W x D 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANS...

Страница 3: ...PUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND...

Страница 4: ...O COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTE...

Страница 5: ...Trove3 Mercury V Kits Installation Guide 5 Notes...

Страница 6: ...RMR LINQ2 Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output curre...

Страница 7: ...ts Installation Guide 7 TM3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 0 45 11 4mm 2 5 63 5mm 2 50 8mm 13 5 342 9mm 13 5 342 9mm 13 5 342 9mm 25 635mm 0 156 3 96mm 1 0 25 4mm 1 0 25 4mm 34...

Страница 8: ...2 768 1mm 14 01 355 9mm 14 01 355 9mm 1 25 31 8mm 1 55 39 4mm 1 78 45 2mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm...

Отзывы: