Altronix Trove T2SSK7F8 Скачать руководство пользователя страница 7

 

Trove2 S2 (Fuse) Kits 

- 7 - 

eFlow Power Supply/Chargers can be Controlled and Monitored while 

Reporting Power/Diagnostics from Anywhere over the Network...

LINQ2 Mounts Inside any Trove Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep 
systems up and running at optimal levels. It facilitates fast and easy installation and set-up, mini-
mizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost 
of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR). 

LINQ2 

Features:

-  UL Listed in the U.S. and Canada.
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN.
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, 
  output state change and unit temperature.
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays.
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources.
-  Email and Windows Dashboard notifications
-  Event log tracks history.
-  Secure Socket Layer (SSL).
-  Programmable via USB or web browser - includes operating software and 6 ft. USB cable.

LINQ2 Module

Altronix eFlow

Power Supply

Network Connection:

Installation, Programming

and Monitoring

Содержание Trove T2SSK7F8

Страница 1: ...4NB Power Supply Charger One 1 eFlow102NB Power Supply Charger Two 2 ACM8 Fused Access Power Controllers Two 2 PD8UL Fused Power Distribution Module One 1 RSB2 Rocker Switch Bracket with Two 2 Rocker...

Страница 2: ...NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in...

Страница 3: ...NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP IN...

Страница 4: ...F4 F5 F6 F7 F8 MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N Altronix ACM8 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM...

Страница 5: ...Trove2 S2 Fuse Kits 5 Notes...

Страница 6: ...6 Trove2 S2 Fuse Kits Notes...

Страница 7: ...Features UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC batte...

Страница 8: ...H x W x D 27 25 x 21 75 x 6 5 692 2mm x 552 5mm x 165 1mm 6 75 171 5mm 8 25 209 5mm 8 00 203 2mm 2 00 50 8mm 2 00 50 8mm 1 25 31 8mm 1 25 31 8mm 5 25 133 4mm 5 25 133 4mm 7 00 177 8mm 1 25 31 8mm 6 25...

Отзывы: