Installation Instructions for T1RAL13F8P8:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having 
jurisdiction. Product is intended for indoor use only. 
1.  Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2.  In order to mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) turn the enclosure upside down. 
 

Punch out the knockout in designated location, on the back of the unit, from outside of the drawer (Fig. 3, pg. 3)

 

Insert the tamper switch into the knockout from outside of the drawer with the button facing outwards and spaded connectors inside 

 

the drawer. Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. 

 

To activate alarm signal open the rack drawer.

3.  Slide the Trove rack enclosure into an open 2U location in the rack cabinet.
4.  Utilizing proper fasteners attach front ears to the rack rails.
5.  Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6.  Make sure that all internal cofigurations (wiring, voltage selection, switch settings, etc.) are complete before mounting backplane back 
 

into enclosure.

7.  Refer to the eFlow Power Supply/Charger Installation Guide for eFlow4NB and eFlow6NB, and corresponding sub-assembly 
 

Installation Guides for ACM8(CB) and PD8UL for further instructions.

Fig. 3

Tamper Switch mounting location

Back of the drawer, 

viewed from outside.

Содержание Trove T1RAL13F8P8

Страница 1: ...cess Power Controller 1 PD8UL Fused Power Distribution Module Installation Guide All registered trademarks are property of their respective owners More than just power Installing Company _____________...

Страница 2: ...g PD8UL Board Input Fuse Rating PD8UL Board Output Fuse Rating DC Aux Output Range VDC Output Range VDC T1RAL13F8P8 7 5A 250V 10A 32V Power Supply 1 24VDC 8 8 2 5A 15A 32V 3 5A 250V 3 5A 250V 20 19 26...

Страница 3: ...nuts Fig 1a pg 3 3 Attach the hinge brackets to the ends of arms using bolts and nuts positioning them as shown on Fig 1b pg 3 4 Make sure that all nuts are tightened Fig 2 Fig 2a 5 Attach the hinge...

Страница 4: ...twards and spaded connectors inside the drawer Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device To activate alarm signal open the rack drawe...

Страница 5: ...VDC OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND...

Страница 6: ...6 T1RAL13F8P8 Notes...

Страница 7: ...T1RAL13F8P8 7 TAL1R Dimensions 18 5 x 15 25 x 0 3125 469 9mm x 387 4mm x 7 9mm 15 25 387 4mm 18 5 469 9mm...

Страница 8: ...1mm 11 175 283 8mm 2 4 61mm 4 57 116 1mm 3 25 82 3mm 26 5 673 1mm 19 482 6mm R 1 27 32 3mm 1 25 4mm 0 55 14mm 3 62 92mm Altronix is not responsible for any typographical errors 140 58th Street Brookly...