- 2 -
T1RAG3F8 Installation Guide
Overview:
Altronix T1RAG3F8 Trove rack kit is pre-assembled and consist of Trove rack enclosure/backplane with factory
installed Altronix power supply/charger and sub-assemblies. Kits accommodate up to two (2) AMAG M4000
modules for up to eight (8) doors in a single enclosure.
Configuration Chart:
Altronix
Model
Number
120VAC
60Hz
Input
Current
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
Nominal DC
Output Voltage Maximum Supply
Current for Main
and Aux. Outputs on
Power Supply board
and ACMS8 Access
Power Controller’s
outputs
Fail-Safe/
Fail-Secure or
Dry Form “C”
Outputs
ACMS8
Board
Input
Fuse
Rating
ACMS8
Board
Output
Fuse
Rating
[DC]
[Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1RAG3F8
3.5A
5A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4
24VDC @ 5.4A
8
15A/
32V
3A/
32V
Hardware and Accessories:
Specifications:
Spacer | 5/16” Pan Head Screw | Lock Nut
Agency Listings:
• CE European Conformity.
Mechanical:
• Black enclosure with ample knockouts for
convenient access.
• Includes: tamper switch, cam lock and
mounting hardware.
• Modular 2U standard EIA 19” drawer with
extendable slides up to 48”.
• Dimensions (H x W x D): 3.375” x 19.0” x 26.5”
(85.8mm x 482.6mm x 673.1mm)
Included Accessories:
• One (1) tamper switch
(Altronix Model TS112 or equivalent).
• Cam lock.
Available Accessories
(not included)
:
•
RE2:
Rack Mount Battery Enclosure
accommodates up to four (4) 12VDC/7AH batteries.
•
WM5, WM25, WM100:
Magnetic Cable Tie Mounts
(5, 25, 100 counts).
Содержание TROVE T1RAG3F8
Страница 6: ... 6 T1RAG3F8 Installation Guide Notes ...
Страница 7: ...T1RAG3F8 Installation Guide 7 Notes ...